Numerical evaluation and experimental validation of cross-flow microfiltration device design.

Biomed Microdevices

Department of Plastics Engineering, University of Massachusetts Lowell, 1 University Avenue, Lowell, MA, 01854, USA.

Published: February 2019

This research presents a comprehensive analysis of the design and validation of a cross-flow microfiltration device for separation of microspheres based on size. Simulation results showed that pillar size, pillar shape, incorporation of back-flow preventers, and rounding of pillar layouts affected flow patterns in a cross-flow microfiltration device. Simulation results suggest that larger pillar sizes reduce filtration capacity by decreasing the density of microfiltration gaps in the device. Therefore, 10 μm rather than 20 μm diameter pillars were incorporated in the device. Fluid flow was not greatly affected when comparing circular, octagonal, and hexagonal pillars. However, side-channel fluid velocities decreased when using triangular and square pillars. The lengths of back-flow prevention walls were optimized to completely prevent back flow without inhibiting filtration ability. A trade-off was observed in the designs of the pillar layouts; while rounding the pillars layout in the channels bends eliminated stagnation areas, the design also decreased side-channel fluid velocity compared to the right-angle layout. Experimental separation efficiency was tested using polydimethylsiloxane (PDMS) and silicon microfluidic devices with microspheres simulating white and red blood cells. Efficiencies for separation of small microspheres to the side channels ranged from 73 to 75%. The silicon devices retained the large microspheres in the main channel with efficiencies between 95 and 100%, but these efficiencies were lower with PDMS devices and were affected by sphere concentration. Additionally, PDMS devices resulted in greater agglomeration of spheres when compared to silicon devices. PDMS devices, however, were easier and less expensive to fabricate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10544-019-0378-9DOI Listing

Publication Analysis

Top Keywords

cross-flow microfiltration
12
microfiltration device
12
pdms devices
12
validation cross-flow
8
pillar layouts
8
side-channel fluid
8
silicon devices
8
devices
6
device
5
pillar
5

Similar Publications

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters.

Biomicrofluidics

January 2024

Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, USA.

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency.

View Article and Find Full Text PDF

The Optimization of Operating Conditions in the Cross-Flow Microfiltration of Grape Marc Extract by Response Surface Methodology.

Foods

December 2023

Programa Institucional de Fomento a la Investigación, Desarrollo e Innovación, Universidad Tecnológica Metropolitana, Ignacio Valdivieso 2409, San Joaquín, Santiago 8940577, Chile.

The recovery of valuable compounds like phenolic compounds and sugars from grape marc extracts implies different steps, including clarification. In this study, a response surface methodology (RSM) was used as a statistical tool to study the effects of operating conditions such as transmembrane pressure (TMP), temperature and feed flow rate on the performance of a microfiltration (MF) monotubular ceramic membrane with a pore size of 0.14 μm in the clarification of grape marc extract from the Carménère variety, as well to optimize the process conditions by implementing the Box-Behnken statistical design.

View Article and Find Full Text PDF

This study investigates the feasibility of a robust, low-cost tubular microfiltration ceramic membrane fabricated using a mixture of locally available Fuller's earth clay (FEC) and solid waste material, rice husk ash (RHA), to treat effluents generated by a local dairy and palm oil industries. Fabrication of the membrane was carried out by employing the extrusion method followed by sintering at a temperature of 850 °C. Raw materials were characterized using XRD, XRF, FTIR, TGA, and differential thermal analysis (DTA).

View Article and Find Full Text PDF

Recent studies on membrane fouling have made considerable progress in reducing its adverse effects. However, a lack of comprehensive studies focusing on the underlying fouling mechanisms remains. This work aims to address a part of this gap by investigating the influence of feed suspension chemistry and operating conditions on the fouling characteristics of microcrystalline cellulose.

View Article and Find Full Text PDF

Continuous precipitation coupled with continuous tangential flow filtration is a cost-effective alternative for the capture of recombinant antibodies from crude cell culture supernatant. The removal of surge tanks between unit operations, by the adoption of tubular reactors, maintains a continuous harvest and mass flow of product with the advantage of a narrow residence time distribution (RTD). We developed a continuous process implementing two orthogonal precipitation methods, CaCl precipitation for removal of host-cell DNA and polyethylene glycol (PEG) for capturing the recombinant antibody, with no influence on the glycosylation profile.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!