Intensity-modulated radiotherapy and volumetric modulated arc therapy are modern radiation therapy technologies that can create the desired dose distribution by multileaf collimator movement and dose-rate control. However, the homogeneous dose delivery of small-field irradiation techniques shows disagreement with that of treatment planning system. The removal of the flattening filter by flattening filter free (FFF) beam irradiation increases dose conformity and further reduces treatment delivery time in radiosurgery. This study aims to investigate the dose distribution of FFF and flattened beams for small-field irradiation by using the 3D gel dosimeter. The N-isopropylacrylamide (NIPAM) polymer gel dosimeter was employed to record the 3D dose distribution. In addition, flattened and FFF beams were compared using the gamma evaluation technique. The use of an FFF accelerator resulted in excellent radiation treatments with short delivery times and low doses to normal tissues and organs. Results also showed that the passing rate increased with the decrease of field size (30 × 30, 20 × 20, and 10 × 10 mm2) at post-irradiation times of 24, 48, 72, and 96 h. The passing rates for each field size were retained at the same level when gamma criteria, namely, distance-to-agreement (DTA) = 3 mm/dose difference (DD) = 3%, were used. Nevertheless, the passing rates for each field size decreased slowly after 48 h when DTA = 2 mm/DD = 2%. The Wilcoxon signed-rank test was used to determine statistical difference with a significant level of p < 0.05. The passing rates of flattened and FFF beams showed no significant difference. The edge enhancement effect in the flattened beam was more evident than in the FFF beam. The 3D NIPAM gel dosimeter can be used for dose verification of small field for radiation therapy with high dose rate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6383886 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0212546 | PLOS |
Pituitary
December 2024
Dipartimento di Medicina Traslazionale, Università Cattolica del Sacro Cuore, Rome, Italy.
Introduction: Empty sella is characterized by a flattened profile of the pituitary gland that represents in most cases only a radiological incidental finding. When endocrine, ophthalmic, and neurological symptoms occur, this condition is described as empty sella syndrome.
Materials And Methods: We searched MEDLINE (PubMed database) with the data filter 2024-2009 using the keywords listed above.
Med Phys
December 2024
Department of Physics, The Verspeeten Family Cancer Centre, London, Ontario, Canada.
Background: Stereotactic arrythmia radioablation (STAR) is a noninvasive technique to treat ventricular tachycardia (VT). Management of cardiorespiratory motion plays an essential role in VT-STAR treatments to improve treatment outcomes by reducing positional uncertainties and increasing dose conformality. Use of an electrocardiogram (ECG) signal, acquired in real-time, as a surrogate to gate the beam has the potential to fulfil that intent.
View Article and Find Full Text PDFMed Phys
December 2024
Division of Ionizing Radiation Metrology, National Institute of Metrology (NIM), Beijing, China.
Background: The clinical use of flattening filter free (FFF) radiotherapy has significantly increased in recent years due to its effective enhancement of dose rates and reduction of scatter dose. A proposal has been made to adjust the incident electron angle of the accelerator to expand the application of FFF beams in areas such as large planning target volumes (PTVs). However, the inherent softening characteristics and non-uniformity of lateral dose distribution in FFF beams inevitably lead to increased dosimetry errors, especially for ionization chambers widely used in clinical practice, which may result in serious accidents during FFF radiotherapy.
View Article and Find Full Text PDFParallel generation of multi-channel chaos is critical to applications, and the key challenge is the simultaneous generation of broadband chaos with multiple channels and low correlation. Here, we experimentally demonstrate a parallel broadband chaos generation scheme using a single long-active-cavity Fabry-Perot (LC-FP) semiconductor laser under optical feedback. The active-cavity length is designed to be 1500 μm, so the power spectrum of chaos is expanded and flattened by the mode-beating effect.
View Article and Find Full Text PDFJ Voice
December 2024
Delsys, Inc., Natick, Massachusetts 01760; Altec, Inc., Natick, Massachusetts 01760; Department of Speech, Language and Hearing Sciences, Boston University, Boston, Massachusetts 02215. Electronic address:
Introduction: People who undergo a total laryngectomy lose their natural voice and depend on alaryngeal technologies for communication. However, these technologies are often difficult to use and lack prosody. Surface electromyographic-based silent speech interfaces are novel communication systems that overcome many of the shortcomings of traditional alaryngeal speech and have the potential to seamlessly incorporate individualized prosody.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!