Introduction: Aortic stenosis is a significant cause of morbidity and mortality in older patients. The advent of transcatheter aortic valve implantation (TAVI) offers an alternative to surgical aortic valve replacement for patients with severe symptomatic aortic stenosis who are at high or intermediate risk of adverse events. Existing evidence highlights the importance of frailty as a predictor of poor outcomes post-TAVI. The objective of this study is to review the operationalisation of frailty instruments for TAVI recipients and determine clinical outcomes and the change in quality of life in frail patients undergoing TAVI.
Methods And Analysis: Methods are reported according to the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols 2015 checklist. We will search relevant databases to identify published, completed but unpublished and ongoing studies. We will include studies of patients with aortic stenosis, diagnosed as frail and who underwent a TAVI procedure that report mortality, clinical outcomes or health-related quality of life. Retrospective or prospective cohort studies, randomised controlled trials and non-randomised controlled trials will be eligible for inclusion. Two researchers will independently screen articles for inclusion, with disagreements resolved by a third reviewer. One researcher will extract data with audit by a second researcher. The risk of bias in studies will be evaluated using the Quality in Prognosis Studies tool. Meta-analysis of mortality, survival curve and the change in quality of life will be performed if appropriate. Subgroup analysis, sensitivity analysis and meta-regression will be performed if necessary.
Ethics And Dissemination: Due to the nature of this study, no ethical issues are foreseen. We will disseminate the results of our systematic review through a peer-reviewed journal.
Trial Registration Number: CRD42018090597.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6377546 | PMC |
http://dx.doi.org/10.1136/bmjopen-2018-024163 | DOI Listing |
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
CJC Open
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.