Purpose: To determine the prevalence and risk factors related to the opacification of the LS-502-1 intraocular lens.

Methods: Cross-sectional study including patients submitted to cataract surgery between January 2010 and March 2012, with implantation of the LS-502-1 intraocular lens. Past medical history was registered and a complete ophthalmologic evaluation, that included best-corrected visual acuity, slit-lamp examination and fundoscopy, was performed. Anterior segment photographs were taken whenever intraocular lens opacification was present.

Results: One hundred and sixty-nine eyes of 154 patients were included, mean age 78.5 ± 7.9 years. The average follow-up after intraocular lens implantation was 65.6 ± 10.0 months. Intraocular lens opacification was seen in 53.3% (n = 90) and presented as one of four different patterns: peripheral (15.6%, n = 14), central (4.4%, n = 4), diffuse (71.1%, n = 64) and superficial white deposits (8.9%, n = 8). There was no statistically significant association with systemic or ophthalmic conditions. In patients with bilateral implantation, intraocular lens opacification in one eye was significantly related to intraocular lens opacification in the fellow eye. A significant variability in opacification was found across intraocular lens serial numbers: the odds ratio for opacification in intraocular lens with serial number beginning with 200003 was 6.0 when comparing with the remaining lenses.

Conclusion: The opacification prevalence of the LS-502-1 intraocular lens was 53.3%, which is the highest ever described for any intraocular lens model. Our results suggest that this occurrence is secondary to an interaction between unknown patient variables and problems related to intraocular lens manufacturing and storage procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1120672119830581DOI Listing

Publication Analysis

Top Keywords

intraocular lens
48
lens opacification
16
intraocular
13
lens
12
ls-502-1 intraocular
12
opacification
8
opacification intraocular
8
lens serial
8
large-scale opacification
4
opacification hydrophilic/hydrophobic
4

Similar Publications

To develop and validate a predictive model for assessing the risk of early postoperative high intraocular pressure (HIOP) following posterior chamber intraocular lens implantation. The clinical data of patients who underwent posterior chamber intraocular lens implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine between May 2023 and April 2024 were retrospectively reviewed. Patients were divided into a modeling group and a validation group with a 7∶3 ratio using computerized random allocation.

View Article and Find Full Text PDF

Clinical Relevance: Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.

Background: To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.

View Article and Find Full Text PDF

Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate visual outcomes and patient satisfaction after bilateral implantation of a new hydrophobic acrylic intraocular lens called Clareon (Alcon) using the mini-monovision technique.

Methods: A single-center, prospective, nonrandomized study was conducted in Tandil (Buenos Aires, Argentina), including patients scheduled for cataract surgery. To achieve mini-monovision, the spherical equivalent was calculated between -0.

View Article and Find Full Text PDF

To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!