A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surface topography of plain nickel-titanium (NiTi), as-received aesthetic (coated) NiTi, and aesthetic NiTi archwires sterilized by autoclaving or glutaraldehyde immersion: A profilometry/SEM/AFM study. | LitMetric

Background And Aim: Surface topography is a crucial factor in bracket sliding mechanics. Literature on surface roughness of aesthetic archwires is scarce, and there is no study on surface topography of such archwires affected by any sterilization methods. The aim of this study was to compare the surface topography of plain nickel-titanium (NiTi) versus as-received aesthetic coated NiTi wires versus aesthetic wires sterilized by autoclaving or glutaraldehyde immersion.

Materials And Methods: This in vitro study was performed on 80 atomic force microscopy (AFM) observations, 160 profilometry observations, and 40 scanning electron microscopy (SEM) images from rectangular wires of the brands 'American Orthodontics, Ortho Organizers, SIA, and Gestenco'. AFM consisted of 8 subgroups of NiTi orthodontic wires, consisting of 4 subgroups of 4 brands of coated orthodontic wires and 4 subgroups of 4 brands of uncoated wires from the same brands. Profilometry consisted of 16 subgroups of NiTi orthodontic wires, consisting of 4 subgroups of 4 brands of coated orthodontic wires and 12 subgroups of 4 brands of uncoated wires from the same brands (4 as-received wire subgroups, 4 autoclaved, and 4 cold-sterilized subgroups). Scanning electron microscopy (SEM) and AFM images were subjectively evaluated. AFM and profilometry data were analysed statistically (α=0.05).

Results: Overall, the difference between surface roughness parameters of coated versus uncoated archwires was not significant (P>0.05). However, surface roughness of brands differed significantly. Mann-Whitney did not show any significant differences between sterilized wires (both sterilization methods together as one group) and unsterilized wires (both unsterilized coated and uncoated as one group) (P>0.460). After excluding plain uncoated NiTi group, the coated wires in 3 sterilization groups (no sterilization, autoclaving, glutaraldehyde) were not significantly different in terms of average overall surface roughness (Ra) and maximum roughness depths (Rq) of different sterilization groups (P>0.1) but the average maximum peak to valley heights (Rz) values of 3 sterilization groups were significantly different (P=0.0415). Dunn test showed that among three post-hoc pairwise comparisons of Rz values, only the comparison of "no sterilization versus autoclaving" was significant (P<0.05) and the other two were non-significant.

Conclusion: Coating might not affect the surface roughness considerably. Brands have different surface roughnesses. Autoclaving but not cold sterilization might affect the surface roughness of coated archwires.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ortho.2019.01.016DOI Listing

Publication Analysis

Top Keywords

surface topography
16
surface roughness
16
orthodontic wires
16
subgroups brands
16
autoclaving glutaraldehyde
12
wires
12
wires brands
12
sterilization groups
12
surface
8
topography plain
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!