A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy and safety of AZD7594, an inhaled non-steroidal selective glucocorticoid receptor modulator, in patients with asthma: a phase 2a randomized, double blind, placebo-controlled crossover trial. | LitMetric

Background: Inhaled corticosteroids reduce inflammation in asthma but chronic use may cause adverse effects. AZD7594, an inhaled non-steroidal selective glucocorticoid receptor modulator, has the potential of an improved risk-benefit profile. We investigated the safety and efficacy of AZD7594 in asthma.

Methods: This phase 2a multi-center, randomized, double-blind, placebo-controlled crossover study enrolled adults with asthma aged 18 to 75 years. Patients were treated with budesonide 200 μg twice daily for 2-3 3 weeks (run in part one). If controlled, as demonstrated by an asthma control questionnaire-5 score of < 1.5, patients entered a three-week run-in (part two) where they received a short acting bronchodilator alone. Thereafter, patients with a fractional exhaled nitric oxide (FNO) ≥25 ppb and pre-dose FEV 40 to 90% predicted were randomized to one of nine treatment sequences. Each patient received placebo and two of three dose levels of AZD7594 (58, 250, 800 μg) once daily via inhalation, in 14-day treatment periods, separated by three-week washout periods. The primary endpoint was the change from baseline in morning trough FEV versus placebo on day 15. Secondary endpoints included measures of airway inflammation and asthma control.

Results: Fifty-four patients were randomized and received at least 1 dose of treatment, 48 patients completed the study. Overall 52 patients received placebo, 34 received AZD7594 58 μg, 34 received AZD7594 250 μg, and 34 received AZD7594 800 μg. AZD7594 800 μg demonstrated a significant improvement in Day 15 morning trough FEVversus placebo (LS means difference 0.148 L 95% CI 0.035-0.261, p = 0.011), with a dose-dependent response seen in the 250 μg (0.076 L -0·036-0·188, p = 0.183) and 58 μg (0·027 L -0·086-0·140, p = 0.683). All secondary endpoints showed statistically significant improvement at the 800 μg dose. All doses demonstrated a significant reduction in FNO at day 15 p < 0.01. No statistically significant difference in plasma cortisol level was observed between AZD7594 and placebo at any dose. AZD7594 was considered safe and well tolerated.

Conclusions: Two-week treatment with AZD7594 demonstrated a favorable risk-benefit profile in patients with mild to moderate asthma. Further clinical studies are needed to fully characterize AZD7594.

Trial Registration: ClinicalTrials.gov number NCT02479412 .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380015PMC
http://dx.doi.org/10.1186/s12931-019-1000-7DOI Listing

Publication Analysis

Top Keywords

azd7594 inhaled
8
inhaled non-steroidal
8
non-steroidal selective
8
selective glucocorticoid
8
glucocorticoid receptor
8
receptor modulator
8
placebo-controlled crossover
8
efficacy safety
4
safety azd7594
4
modulator patients
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!