Optical thin section observations represent the core empirical basis for most micromorphological interpretations at archaeological sites. These observations, which often vary in size and shape, are usually documented through digital graphic representations such as photomicrographs, scans, or figures. Due to variability in documentation practices, however, visual thin section data can be captured with a range of methods and in many different formats and resolutions. In this paper, we compare and evaluate five common image-based methods for documenting thin sections in high-resolution: a flatbed scanner, a film scanner, a macro photography rig, and conventional stereo and light microscopes. Through the comparison results, we demonstrate that advances in digital imaging technology now allow for fast and high-resolution visual recording of entire thin sections up to at least ×30 magnification. We suggest that adopting a digital micromorphological documentation practice has several advantages. First, a digital thin section may be observed more efficiently and consistently, for example, on a computer screen, and the spatial configuration of large or complex features may be more accurately documented. Second, they allow for the establishment of digital repositories that may promote scientific reproducibility and inter-laboratory communication, as well as lay the foundations for more consensus-based educational training of archaeological micromorphology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6358115PMC
http://dx.doi.org/10.1002/gea.21706DOI Listing

Publication Analysis

Top Keywords

thin sections
12
sections high-resolution
8
thin
6
digital
5
documenting archaeological
4
archaeological thin
4
high-resolution comparison
4
comparison methods
4
methods discussion
4
discussion applications
4

Similar Publications

Background: Neuropathological tau tangles in Alzerheimer's disease (AD) have been roughly characterized into pre-tangles, mature tangles and ghost tangles. However, to date, their maturation in the human brain is poorly understood. Here, we aimed to define the structure and composition of tangle maturation stages in the AD brain using correlative light and electron microscopy (CLEM).

View Article and Find Full Text PDF

Aim: To evaluate risk indicators for gingival recessions (GRs) in the lower anterior teeth of orthodontic patients post treatment and during a retention period of at least 5 years, compared to non-treated controls.

Material And Methods: Eighty-nine orthodontically treated patients who were recession-free before treatment were recruited. Demographic, cephalometric and occlusal records were retrieved before (T1) and after treatment (T2), and periodontal outcomes were clinically evaluated at least 5 years post retention (T3).

View Article and Find Full Text PDF

The sound absorption structure of a microperforated plate has many advantages and has great potential in the field of noise control. In order to solve the problem of broadband sound absorption of microperforated plates, a series acoustic structure of microperforated plates of unequal cross-section was designed based on the traditional microperforated plate series acoustic structure. Compared with the traditional series structure, the sudden change of cross-section increases the sound energy dissipation and greatly improves the sound absorption performance.

View Article and Find Full Text PDF

The article provides information about strengthening cold-formed thin-walled steel beams made of the sigma profile. An innovative concept for sectional transverse strengthening of thin-walled beams subjected to concentrated forces was investigated. The proposed solution's novelty lies in attaching the sectional transverse strengthening to the beam's cross-section, employing a point crimping technique.

View Article and Find Full Text PDF

Artificial Intelligence Unveils the Unseen: Mapping Novel Lung Patterns in Bronchiectasis via Texture Analysis.

Diagnostics (Basel)

December 2024

Department of Respiratory Medicine, JSS Medical College, JSS Academy of Higher Education & Research (JSS AHER), Mysore 570004, Karnataka, India.

Thin-section CT (TSCT) is currently the most sensitive imaging modality for detecting bronchiectasis. However, conventional TSCT or HRCT may overlook subtle lung involvement such as alveolar and interstitial changes. Artificial Intelligence (AI)-based analysis offers the potential to identify novel information on lung parenchymal involvement that is not easily detectable with traditional imaging techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!