Thoracic aortic endovascular repair (TEVAR) is increasingly preferred as a treatment of choice in thoracic aortic diseases. Intravascular foreign body is one of the TEVAR-related complications similar to the other endovascular operations. Here, to the our best knowledge for the first time in the English literature, this report presents an extremely rare complication of a broken and stuck tip part of aortic stent-graft in the intravascular space and successful removal by using the coaxial technique. Thoracic aortic endovascular repair (TEVAR) has been increasingly preferred as the treatment of choice in thoracic aortic diseases (1). Endovascular treatment has been gaining popularity compared with open surgery due to its less invasive approach and rapid application, and allows the patient to easily return to daily life (2). However, TEVAR is associated with several specific complications including paraplegia, stroke, vascular injuries and local complications. These complications depend on vascular or nonvascular comorbidities, vascular anatomy, equipment, and experience of the provider (3-6). Intravascular foreign body could be among TEVAR-related complications similar to other endovascular operations (7). Several types of equipment, including guidewire, vascular sheath, or suboptimally uncoiled stents may get stuck in the intravascular space, causing complications (8). Herein, to the best of our knowledge, we present the first report in the English literature of broken and stuck tip part of an aortic stent-graft in the intravascular space and its successful removal using the coaxial technique.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411261 | PMC |
http://dx.doi.org/10.5152/dir.2019.18263 | DOI Listing |
Chin Med
January 2025
Aging and Metabolism Research Group, Korea Food Research Institute, Wanju‑gun, 55365, Republic of Korea.
Background: Magnolia kobus DC (MO), as a plant medicine, has been reported to have various physiological activities, including neuroprotective, anti-inflammatory, and anti-diabetic effects. However, vascular protective effects of MO remain incompletely understood. In this study, we evaluated the vascular protective effect of MO against ferroptosis in a carotid artery ligation (CAL)-induced neointimal hyperplasia mouse model and in aortic thoracic smooth muscle A7r5 cells.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].
View Article and Find Full Text PDFSci Rep
January 2025
Department of Cardiovascular Surgery, Nihon University Hospital, Itabashi-ku, Tokyo, Japan.
We investigated the influence of false lumen (FL) status on the systemic inflammatory response triggered by acute aortic dissection (AAD) using cytokine profiling. The study included 44 patients with AAD. Patients were divided between those with a thrombosed FL (Group T, n = 21) and those with a non-thrombosed FL (Group P, n = 23).
View Article and Find Full Text PDFSci Rep
January 2025
Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China.
It remains controversial as to which optimal cannulation strategy ought to be employed in surgery for type A aortic dissection (TAAD). The aim of this study was to make a comparison of the clinical outcomes between single and double arterial cannulation. From January 2018 to December 2022, 403 individuals with TAAD were recruited for the study and were divided into two groups based on the cannulation approach.
View Article and Find Full Text PDFJ Med Genet
January 2025
Center of Medical Genetics, University of Antwerp and Antwerp University Hospital, Antwerp, Belgium.
Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.
Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!