Despite significant advances in the design of metallic materials for bare metal stents (BMSs), restenosis induced by the accumulation of smooth muscle cells (SMCs) has been a major constraint on improving the clinical efficacy of stent implantation. Here, a new strategy for avoiding this issue by utilizing hydrogen peroxide (HO) generated by the galvanic coupling of nitinol (NiTi) stents and biodegradable magnesium-zinc (Mg-Zn) alloys is reported. The amount of HO released is carefully optimized via the biodegradability engineering of the alloys and by controlling the immersion time to selectively inhibit the proliferation and function of SMCs without harming vascular endothelial cells. Based on demonstrations of its unique capabilities, a fully metallic stent with antirestenotic functionality was successfully fabricated by depositing Mg layers onto commercialized NiTi stents. The introduction of surface engineering to yield a patterned Mg coating ensured the maintenance of a stable interface between Mg and NiTi during the process of NiTi stent expansion, showing high feasibility for clinical application. This new concept of an inert metal/degradable metal hybrid system based on galvanic metal coupling, biodegradability engineering, and surface patterning can serve as a novel way to construct functional and stable BMSs for preventing restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.8b03753DOI Listing

Publication Analysis

Top Keywords

fully metallic
8
niti stents
8
biodegradability engineering
8
interface engineering
4
engineering fully
4
stents
4
metallic stents
4
stents enabling
4
enabling controllable
4
controllable generation
4

Similar Publications

As novel promising anticancer candidates, the piano-stool type complexes of ruthenium, [RuCl(η-p-cymene)(N,S-L)]PF, K-, were synthesized from the reaction of the substituted benzo[b]thiophene based thiosemicarbazone ligands (L) with [{RuCl(η-p-cymene)}(μ-Cl)]. All complexes were fully characterized using elemental analysis, and spectroscopic methods such as FT-IR and H NMR. The molecular masses of the complexes were proved by MALDI-TOF analysis.

View Article and Find Full Text PDF

Redox-active Co(II) and Zn(II) Pincer Complexes as High-Capacity Anode Materials for Lithium-Ion Batteries.

Adv Sci (Weinh)

December 2024

Department of Chemistry and Research Institute of Molecular Alchemy, Gyeongsang National University, Jinju, 52828, South Korea.

To address the ongoing demand for high-performance energy storage devices, it is crucial to identify new electrode materials. Lithium-ion batteries (LIBs) store energy via the electrochemical redox process, so their electrode materials should have reversible redox properties for rechargeability. On that note, redox-active metal complexes are explored as innovative electrode materials for LIBs.

View Article and Find Full Text PDF

Intracerebral hemorrhage (ICH) is a common cerebrovascular disease characterized by a high incidence, disability rate, and mortality. Epigallocatechin gallate (EGCG), a key catechin compound found in green tea, has received increasing attention for its potential neuroprotective and therapeutic effects in neurological disorders. Studies have indicated that EGCG may influence various signaling pathways and molecular targets, including the inhibition of oxidative stress, reduction of inflammatory responses, suppression of cell apoptosis, regulation of cell survival, and enhancement of autophagy.

View Article and Find Full Text PDF

This study investigates radiomic efficacy in post-surgical traumatic spinal cord injury (SCI), overcoming MRI limitations from metal artifacts to enhance diagnosis, severity assessment, and lesion characterization or prognosis and therapy guidance. Traumatic spinal cord injury (SCI) causes severe neurological deficits. While MRI allows qualitative injury evaluation, standard imaging alone has limitations for precise SCI diagnosis, severity stratification, and pathology characterization, which are needed to guide prognosis and therapy.

View Article and Find Full Text PDF

A Highly Stable Electrochemical Sensor Based on a Metal-Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat.

Biosensors (Basel)

December 2024

Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.

The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.

View Article and Find Full Text PDF