Objectives: This study sought to describe the procedural and clinical outcomes of patients undergoing transcarotid (TC) transcatheter aortic valve replacement (TAVR) with the Edwards Sapien 3 device.

Background: The TC approach for TAVR holds the potential to become the optimal alternative to the transfemoral gold standard. Limited data exist regarding safety and efficacy of TC-TAVR using the Edwards Sapien 3 device.

Methods: The French Transcarotid TAVR prospective multicenter registry included patients between 2014 and 2018. Consecutive patients treated in 1 of the 13 participating centers ineligible for transfemoral TAVR were screened for TC-TAVR. Clinical and echocardiographic data were prospectively collected. Perioperative and 30-day outcomes were reported according to the updated Valve Academic Research Consortium (VARC-2).

Results: A total of 314 patients were included with a median (interquartile range) age of 83 (78 to 88) years, 63% were males, Society of Thoracic Surgeons mortality risk score 5.8% (4% to 8.3%). Most patients presented with peripheral artery disease (64%). TC-TAVR was performed under general anesthesia in 91% of cases, mostly using the left carotid artery (73.6%) with a procedural success of 97%. Three annulus ruptures were reported, all resulting in patient death. At 30 days, rates of major bleeding, new permanent pacemaker, and stroke or transient ischemic attack were 4.1%, 16%, and 1.6%, respectively. The 30-day mortality was 3.2%.

Conclusions: TC-TAVR using the Edwards Sapien 3 device was safe and effective in this prospective multicenter registry. The TC approach might be considered, in selected patients, as the first-line alternative approach for TAVR whenever the transfemoral access is prohibited. Sapien 3 device was safe and effective in our multicenter cohort.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2018.11.014DOI Listing

Publication Analysis

Top Keywords

edwards sapien
12
valve replacement
8
approach tavr
8
tc-tavr edwards
8
prospective multicenter
8
multicenter registry
8
sapien device
8
device safe
8
safe effective
8
patients
6

Similar Publications

Background: Transcatheter aortic valve implantation (TAVI) has shown similar or improved clinical outcomes compared with surgical aortic valve replacement (SAVR) in patients with symptomatic severe aortic stenosis at low risk for surgical mortality. This cost-utility analysis compared TAVI with SAPIEN 3 versus SAVR in symptomatic severe aortic stenosis patients at low risk of surgical mortality from the perspective of the Swedish healthcare system.

Methods: A published, two-stage, Markov-based cost-utility model that captured clinical outcomes from the (SWEDEHEART) registry (2018-2020) was adapted from the perspective of the Swedish healthcare system using local general population mortality, utility and costs data.

View Article and Find Full Text PDF

Background: The Edwards Sapien percutaneous valve (Edwards Lifesciences, Irvine, CA, USA) is a promising therapeutic option for congenital atrioventricular disease mostly because of the possibility to accommodate somatic growth with balloon dilatation.

Case Summary: This article reports the performance of the Edwards Sapien 3 valve in atrioventricular valve position in four paediatric patients.

Discussion: Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth.

View Article and Find Full Text PDF

Background: Balloon-assisted bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BA-BASILICA) enables valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in patients at risk of coronary artery obstruction. However, its efficacy in patients with severely calcified leaflets remains unclear.

Case Summary: We report a 78-year-old woman with a deteriorated 21 mm Carpentier-Edwards PERIMOUNT Magna valve.

View Article and Find Full Text PDF

Background: No data compare newer-generation transcatheter heart valves (THVs) in terms of next-day discharge (NDD) following transfemoral (TF) transcatheter aortic valve implantation (TAVI).

Aims: We aimed to evaluate the safety of NDD in unselected patients who received ACURATE (neo/neo2), Evolut (PRO/PRO+/FX) and the SAPIEN (3/Ultra) THVs.

Methods: This multicentre registry included patients who underwent TF-TAVI without a preprocedural permanent pacemaker implantation (PPI) and were discharged the next day without a new PPI.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR)-in-TAVR within index supra-annular transcatheter heart valves (THVs) and high-risk anatomy can compromise coronary perfusion and re-access.

Case Summary: An 80-year-old male presented with acute heart failure caused by degeneration of an Evolut R THV, leading to severe aortic regurgitation. Aortic computed tomography imaging revealed a high-risk anatomy characterized by the index THV's commissural plane being placed above the coronary ostia and a valve-to-aorta distance of less than 2 mm, resulting not eligible for redo-TAVR according to recent literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!