Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The simultaneous quantitative analysis of intracellular metabolic coenzymes flavin adenine dinucleotide (FAD) and flavin mononucleotide (FMN) is of interest because they participate in many electron-transfer reactions of metabolism. But, the simultaneous quantitative analysis of FAD and FMN is hard to be achieved by traditional analytical methods. This paper proposes a novel strategy of intrinsic fluorescence coupled with four-way calibration method for simultaneous quantitative analysis of intracellular metabolic coenzymes FAD and FMN. Through mathematical separation, this proposed analytical method efficiently achieved the simultaneous quantitative analysis of metabolic coenzymes FAD and FMN in the cell, despite the fact that uncalibrated spectral interferents coexist in the system. The predicted concentrations of FAD and FMN in the cell are 217.0 ± 6.9 and 155.0 ± 1.7 pmol/10 cells respectively, which were validated by the approved liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. This analytical method with second-order advantage simply requires the cell solution to be diluted by a buffer, it could introduce an interesting analytical strategy for multianalyte direct quantitative analysis in complex biological systems. In addition, we explore the third-order advantage of four-way calibration by a comparative study based on this real fluorescence data. The comparisons indicate that a four-way calibration method can provide higher sensitivity and more resolving power than a three-way calibration method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2018.12.076 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!