Background: The treatment of glenoid bone deficiencies in primary or revision total shoulder arthroplasty is challenging. This retrospective study evaluated the short-term clinical and radiologic results of a new custom-made patient-specific glenoid implant.

Methods: We treated 10 patients with severe glenoid deficiencies with the Glenius Glenoid Reconstruction System (Materialise NV, Leuven, Belgium). Outcome data included a patient-derived Constant-Murley score, a visual analog score (VAS), a satisfaction score, the 11-item version of the Disabilities of the Arm, Shoulder and Hand score, and the Simple Shoulder Test. We compared the postoperative position of the implant with the preoperative planned position on computed tomography scans.

Results: At an average follow-up period of 30.5 months, the mean patient-derived Constant-Murley score was 41.3 ± 17.5 points (range, 18-76 points) with a visual analog scale of 3.3 ± 2.5 points (range, 0-7 points). The mean 11-item version of the Disabilities of the Arm, Shoulder and Hand score was 35.8 ± 18.4 (range, 2-71), and the mean Simple Shoulder Test was 47.5% ± 25.3% (range, 8%-92%). Eight patients reported the result as better (n = 3) or much better (n = 5). One patient had an elongation of the brachial plexus, and 1 patient had a period of instability. The average preoperative glenoid defect size was 9 ± 4 cm (range, 1-14 cm). The mean deviation between the preoperative planned and the postoperative version and inclination was 6° ± 4° (range 1°-16°) and 4° ± 4° (range 0°-11°), respectively.

Conclusion: Early results of the Glenius Glenoid Reconstruction System are encouraging. Adequate pain relief, a reasonable functionality, and good patient satisfaction can be obtained in these difficult cases. Further follow-up will determine the bony ingrowth and subsequent longevity of this patient-specific glenoid component.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2018.11.061DOI Listing

Publication Analysis

Top Keywords

glenius glenoid
12
glenoid reconstruction
12
reconstruction system
12
glenoid
9
severe glenoid
8
glenoid deficiencies
8
shoulder arthroplasty
8
patient-specific glenoid
8
patient-derived constant-murley
8
constant-murley score
8

Similar Publications

Functional and Radiological Outcomes after Treatment with Custom-Made Glenoid Components in Revision Reverse Shoulder Arthroplasty.

J Clin Med

January 2022

Department of Orthopedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 4020 Linz, Austria.

Glenoid implant position and fixation are challenging in severe glenoid defects in reverse total shoulder arthroplasty (rTSA). Custom-made glenoid implants are metal augmented implants that are specially produced for a certain defect. They provide the restoration of the joint line and proper fixation.

View Article and Find Full Text PDF

Background: The treatment of glenoid bone deficiencies in primary or revision total shoulder arthroplasty is challenging. This retrospective study evaluated the short-term clinical and radiologic results of a new custom-made patient-specific glenoid implant.

Methods: We treated 10 patients with severe glenoid deficiencies with the Glenius Glenoid Reconstruction System (Materialise NV, Leuven, Belgium).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!