In this paper, complete complementary code (CCC) sequences are applied to a High Frequency (HF) ionospheric sounding network. Ionosondes distributed at multiple locations use the mutually orthogonal CCC sequences to conduct vertical soundings synchronously. At the same time, thanks to the omnidirectional antennas, every station can receive the oblique echoes transmitted from the others. Due to the orthogonality between the code sequences, both vertical and oblique ionograms can be simultaneously obtained and completely separated. Through this method, the sounding efficiency can be enhanced, and the inversion difficulty can be reduced. Further, by using the data assimilation method, vertical and oblique sounding results can be combined to obtain a wide range of regional ionospheric characteristics. To verify the performance of this kind of sounding network, validation experiments are implemented to demonstrate that vertical and oblique ionograms can be obtained independently at the same time and inverted separately and that the maps of foF2 parameters obtained by using the data assimilation method provide more details than single vertical or oblique sounding.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412486PMC
http://dx.doi.org/10.3390/s19040779DOI Listing

Publication Analysis

Top Keywords

vertical oblique
16
sounding network
12
ionospheric sounding
8
complete complementary
8
complementary code
8
ccc sequences
8
oblique ionograms
8
data assimilation
8
assimilation method
8
oblique sounding
8

Similar Publications

Canine tooth syndrome after frontoethmoidal osteoma surgery: a case report.

Strabismus

January 2025

Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.

: Canine tooth syndrome is a rare condition defined by the simultaneous presence of superior oblique palsy and Brown syndrome, resulting from pathological changes in the trochlear region. This syndrome can develop through various mechanisms, including dog bites, head trauma, infections, inflammation, and scarring. This report highlights its occurrence following sinus surgery for the first time.

View Article and Find Full Text PDF

Botulinum toxin A (BTX) injected into the inferior oblique muscle temporarily simulates the post-operative effect of an inferior oblique myectomy (IOM). This can aid in surgical planning, especially given the irreversible nature of IOM. This study evaluates the efficacy of BTX as a pre-operative simulator and compares its effects to those of IOM.

View Article and Find Full Text PDF

[Diagnostic and therapeutic approach to unilateral posterior vertical insufficiency].

Orthod Fr

January 2025

Nantes Université, Université Angers, CHU Nantes, INSERM, CNRS, CRCI2NA, 44000 Nantes, France

Introduction: The aim of this article is to present the diagnostic and therapeutic approach to unilateral posterior vertical insufficiency.

Material And Methods: The authors describe the management protocol.

Results: Posterior vertical insufficiency (PVI) manifests clinically as obliquity of the maxillo-mandibular occlusal plane and bicommissural line, and deviation of the chin.

View Article and Find Full Text PDF

Introduction: Global coronal alignment is mainly assessed by C7 plumbline and central sacral vertical line (CSVL), pelvic obliquity and shoulder alignment. A detailed analysis is mandatory when treating spinal deformity. It remains unclear to what extent mild scoliosis influences global coronal alignment.

View Article and Find Full Text PDF

Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?

J Radiol Prot

January 2025

Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany.

With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm,(3), is the measurement method for monitoring the dose to the lens of the eye. Usual dosemeter type-test irradiations at non-normal angles of radiation incidence (≠ 0°) primarily use lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating rotation of the dosemeter-phantom setup around a vertical axis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!