Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Int J Environ Res Public Health

Department of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, 20123 Milan, Italy.

Published: February 2019

The aim of this in vitro study was to compare the quality of digital workflows generated by different scanners (Intra-oral digital scanners (I.O.S.s)) focusing on marginal fit analysis. A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in hemi-maxillary stone model and scanned by eight different I.O.S.s: Omnicam (Denstply Sirona, Verona, Italy) CS3500, CS3600, (Carestream Dental, Atlanta, GA, USA), True Definition Scanner (3M, St. Paul, MN, USA), DWIO (Dental Wings, Montreal, Quebec, Canada), PlanScan (Planmeca Oy, Helsinki, Finland), 3D PROGRESS Plus (MHT, Verona, Italy), TRIOS 3 (3Shape, Copenhagen, Denmark). Nine scans were performed by each tested I.O.S. and 72 copings were designed using a dental computer-assisted-design/computer-assisted-manufacturing (CAD/CAM) software (exocad GmbH, Darmstadt, Germany). According to CAD data, zirconium dioxide (ZrO₂) copings were digitally milled (Roland DWX-50, Irvine, CA, USA). Scanning electron microscope (SEM) direct vision allowed for marginal gap measurements in eight points for each specimen. Descriptive analysis was performed using mean, standard deviation, and median, while the Kruskal⁻Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (significance level < 0.05). The overall mean marginal gap value and standard deviation were 53.45 ± 30.52 μm. The minimum mean value (40.04 ± 18.90 μm) was recorded by PlanScan, then 3D PROGRESS Plus (40.20 ± 21.91 μm), True Definition Scanner (40.82 ± 26.19 μm), CS3500 (54.82 ± 28.86 μm) CS3600 (59,67 ± 28.72 μm), Omnicam (61.57 ± 38.59 μm), DWIO (62.49 ± 31.54 μm), while the maximum mean value (67.95 ± 30.41 μm) was recorded by TRIOS 3. The Kruskal⁻Wallis tests revealed a statistically significant difference (-value < 0.5) in the mean marginal gaps between copings produced by 3D PROGRESS Plus, PlanScan, True Definition Scanner, and the other evaluated I.O.S.s. The use of an I.O.S. for digital impressions may be a viable alternative to analog techniques. Although in this in vitro study PlanScan, 3D PROGRESS Plus and True Definition Scanner may have showed the best performances, all I.O.S.s tested could provide clinically encouraging results especially in terms of marginal accuracy, since mean marginal gap values were all within the clinically acceptable threshold of 120 μm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6406818PMC
http://dx.doi.org/10.3390/ijerph16040544DOI Listing

Publication Analysis

Top Keywords

true definition
16
definition scanner
16
marginal gap
12
μm
10
marginal
8
marginal accuracy
8
vitro study
8
verona italy
8
standard deviation
8
μm recorded
8

Similar Publications

Drug Development.

Alzheimers Dement

December 2024

KU Leuven and Universiteit Hasselt, Leuven, Vlaams-Brabant, Belgium.

An overview is given of surrogate marker evaluation, starting from the original definition of Prentice and his criteria, the estimation framework of Freedman, the meta-analytic framework, and the evaluation of surrogate endpoints from a causal inference point of view. Attention will be given, in particular, to evaluating tau-PET as a reasonably likely surrogate in Alzheimer's Disease. A meta-analytic surrogate marker evaluation approach will be followed, for a continuous surrogate and a continuous true endpoint.

View Article and Find Full Text PDF

The combination of hip arthroscopy and periacetabular osteotomy (PAO) has been proven safe and effective for addressing symptoms in patients with developmental dysplasia of the hip (DDH). As not every patient with dysplasia will require a hip arthroscopy to obtain desired clinical improvement in the setting of periacetabular osteotomy, a challenge is identifying which patients require adjacent procedures (either via arthroscopic or open) to fully treat their hip pathology. Even though labral repair is the most reported arthroscopic procedure in cases of hip dysplasia, I would suggest that labral treatment is the least likely helpful component of hip arthroscopy in these cases.

View Article and Find Full Text PDF

Background: The presence of a human tail is a rare condition resulting from an embryonic remnant that fits the definition of a caudal appendage. It may be a vestigial (true) or a pseudotail. Both may be considered markers of underlying intraspinal abnormalities.

View Article and Find Full Text PDF

Mapping Consumer Preference for Vegan and Omnivorous Diets for the Sensory Attributes of Flour Products with Iodine-Fortified Plant-Based Ingredients.

Nutrients

December 2024

Department of Gastronomy Science and Functional Foods, Faculty of Food Science and Nutrition, Poznań University of Life Sciences, Wojska Polskiego 31, 60-624 Poznań, Poland.

Objectives: Flour products with iodine-fortified dried vegetables can be a good source of iodine. However, in addition to iodine stability, the sensory quality of these products is also important. Therefore, this study aimed to assess the effect of adding iodine-fortified dried vegetables to flour products (gnocchi and ciabatta) on their sensory quality and map consumers (vegan/omnivore diets) as potential consumers of fortified flour products with iodine-fortified dried vegetables.

View Article and Find Full Text PDF

Background: Histological findings of infective endocarditis (IEs) in mechanical valves present a complex diagnostic challenge owing to the lack of a precise definition. This ambiguity is further complicated by the natural degenerative processes that occur in the mechanical valves over time. Consequently, pathologists and clinicians face significant difficulties in distinguishing between genuine infective processes and the normal wear and tear of mechanical valves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!