The aim of this study is to implement the clinical use of the three-dimensional (3D) design and printing technology in pediatric pathologies requiring immobilization. We describe the manufacturing process of the 3D device in place of the plaster cast usually applied to a child 48/72 h after the access to the Trauma Center Traumatology Hub. This procedure had already been performed at Level II, Trauma Center, Campania Region, Orthopaedic Division of Santobono Children's Hospital, Naples, Italy. The operative phase was performed by two 3D printers and a scanner in the bioengineering laboratory of the hospital's outpatient area. The phase of software elaboration requires close cooperation among physicians and engineers. We decided to use a model with a double-shell design and holes varying in width to ensure complete ventilation and lightness of the device. We chose to treat nondisplaced metaphyseal distal fractures of the radius in 18 patients enrolled from January 2017 to November 2017. The flow chart includes clinical and radiological examinations of every enrolled child, collecting information required by the program and its elaboration by bioengineers, and then transfer of the results to 3D printers. The child, immobilized by a temporary splint, wore his 3D device after 12/24 h. Then, he underwent serial check-ups in which the effectiveness and appropriateness of the treatment were clinically monitored and evaluated using subjective scales: visual analogue scale and patient-rated wrist evaluation. All the fractures consolidated both radiologically and clinically after the treatment, with no complications reported. Only one partial breakage of the device happened because of an accidental fall. The statistical analysis of the visual analogue scale and patient-rated wrist evaluation data shows that children's activities of everyday life improved during the immobilization thanks to this treatment. This first study shows that using a 3D device instead of a traditional plaster cast can be an effective alternative approach in the treatment of pediatric nondisplaced metaphyseal distal radius fractures, with high overall patient satisfaction. We believe that 3D technology could be extended to the treatment of more complex fractures; this will be the subject of our second study.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPB.0000000000000589DOI Listing

Publication Analysis

Top Keywords

plaster cast
12
trauma center
12
treatment pediatric
8
nondisplaced metaphyseal
8
metaphyseal distal
8
visual analogue
8
analogue scale
8
scale patient-rated
8
patient-rated wrist
8
wrist evaluation
8

Similar Publications

Is percutaneous heel cord tenotomy a necessary component in the Ponseti treatment of idiopathic clubfoot deformity?

J Pediatr Orthop B

January 2025

Department of Orthopaedic Surgery, Scottish Rite for Children, Dallas, Texas, USA.

This study aimed to compare outcomes of idiopathic clubfeet (IC) treated with a percutaneous heel cord tenotomy (PHCT) at the conclusion of Ponseti casting with those that were not. A retrospective review of patients enrolled in a single institution prospective clubfoot registry over 19 years was performed. Patients under the age of 3 months with untreated IC managed via the Ponseti method that had a minimum of 2 years follow-up were included.

View Article and Find Full Text PDF

Purpose: To evaluate the rate of missed scaphoid fractures on follow-up computed tomography (CT) for suspected occult scaphoid fracture after normal radiography with residual radial-sided wrist pain.

Methods: In a retrospective analysis, wrist CT during a five-year period was analyzed. The CT examinations and radiological reports were re-evaluated.

View Article and Find Full Text PDF

Introduction: The goal of this work is to determine, using the analysis of our own patient group and current professional publications, in which cases fractures of the scaphoid waist can be treated conservatively by short-term plaster fixation with a low risk of non-union developing.

Material And Method: A group of 19 patients (17 men and 2 women) with the mean age 31 years (range 20-43, SD 7.3) with fractures of scaphoid waist were indicated for conservative treatment.

View Article and Find Full Text PDF

Background: Non-invasiveness and comfort are crucial in the conservative management of distal radius and scaphoid fractures. While fiberglass casts are standard, three-dimensional (3D)-printed orthoses offer a promising alternative.

Purpose: To compare patient experiences, safety perceptions, and satisfaction between a 3D orthosis and fiberglass cast for distal radius or scaphoid fractures.

View Article and Find Full Text PDF

Purpose: The study was performed to examine the error associated with image superimposition when computed tomography (CT) images of the dental region are substituted with dental scan data, according to the block-out material used in dental impressions.

Materials And Methods: A typodont model was created by bonding orthodontic brackets to teeth on plaster dental stones using melted dental base-plate wax. In the experiment, 2 groups were compared: one using wax and the other using putty as the block-out material to prevent tearing of the impression material during the acquisition of dental impressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!