We report the first observation of the spontaneous polarization of Λ and Λ[over ¯] hyperons transverse to the production plane in e^{+}e^{-} annihilation, which is attributed to the effect arising from a polarizing fragmentation function. For inclusive Λ/Λ[over ¯] production, we also report results with subtracted feed-down contributions from Σ^{0} and charm. This measurement uses a dataset of 800.4 fb^{-1} collected by the Belle experiment at or near a center-of-mass energy of 10.58 GeV. We observe a significant polarization that rises with the fractional energy carried by the Λ/Λ[over ¯] hyperon.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.122.042001 | DOI Listing |
Prostate Cancer
April 2020
Department of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP, Eindhoven, Netherlands.
Objective: To compare prostate cancer detection rates (CDRs) and pathology results with targeted prostate biopsy (TB) and systematic prostate biopsy (SB) in biopsy-naive men.
Methods: An in-patient control study of 82 men undergoing SB and subsequent TB in case of positive prostate MRI between 2015 and 2017 in the Jeroen Bosch Hospital, the Netherlands.
Results: Prostate cancer (PCa) was detected in 54.
BMC Urol
April 2019
Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Background: To overcome the limitations regarding two dimensional (2D) greyscale (GS) transrectal ultrasound (TRUS)-guided biopsy in prostate cancer (PCa) detection and tissue packaging in biopsy processing, there is an ongoing focus on new imaging and pathology techniques. A three-dimensional (3D) model of the prostate with biopsy needle guidance can be generate by the Navigo™ workstation (UC-care, Israel). The SmartBX™ system (UC-care, Israel) provides a prostate biopsy core preembedding method.
View Article and Find Full Text PDFWorld J Urol
June 2018
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Purpose: To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens.
Methods: Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!