A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Turbidity control on dissolved air flotation process using fuzzy logic. | LitMetric

Turbidity control on dissolved air flotation process using fuzzy logic.

Water Sci Technol

School of Chemical Engineering, University of Campinas, 500 Albert Einstein Avenue, ZIP 13083-970, Campinas, SP, Brazil E-mail:

Published: December 2018

This study intends to explore fuzzy logic control on clean water turbidity process with dissolved air flotation (DAF). Three different strategies were tested to regulate clean water turbidity by manipulating the saturator vessel flow output aiming for low actuators control effort. Saturator pressure was the manipulated variable (MV) in the first control loop named SISO I. The second control loop, SISO II, used recycle stream valve opening as MV. The third control loop (MISO) was developed applying fuzzy logic instead PID control. Several performance criteria were used to analyze the process control performance such as integral absolute error (IAE), recycle stream valve and saturator vessel pressure regulating valve control efforts, ECV and ECV respectively. Results from SISO I and SISO II strategies showed that recycle stream is a better MV than saturator vessel pressure for clean water turbidity control in the DAF process. Only SISO II and MISO strategies proved to be capable of regulating the process variable. However, MISO control showed better performance based on IAE value against SISO II, with a reduction of 11.24% on its value, even the recycle stream valve control effort for MISO control being fairly higher than that for SISO II. Nevertheless, fuzzy logic control application gave rise to better turbidity control, and consequently prevented the excessive use of clean water in the recycling stream.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2019.015DOI Listing

Publication Analysis

Top Keywords

fuzzy logic
16
clean water
16
recycle stream
16
control
14
turbidity control
12
water turbidity
12
saturator vessel
12
control loop
12
stream valve
12
dissolved air
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!