Age estimation based on visual parameters of the skin of cadavers.

Skin Res Technol

Department of Forensic Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.

Published: July 2019

Background: Previous studies have reported relationships between various visual parameters of the skin and changes due to aging. Due to an increase in the discovery of unidentified bodies, the field of forensic medicine anticipates the development of a rapid method for estimating age. The present study measured various visual parameters of the skin in human remains and investigated the correlation between these parameters and age.

Materials And Methods: Skin images were taken of four body parts (cheek, chin, brachium, and thigh) of 414 forensic cases. We interpreted eight visual parameters of the skin (smoothness, roughness, texture, dullness, brightness, erythema, color phase, and sagging) from skin photograph images, and constructed three age-prediction models, categorized by sex, postmortem interval, and age.

Results: Significant correlations were observed in the erythema of the cheek and chin, the roughness of the brachium, and the texture of the brachium and thigh among the visual parameters calculated in four body parts, using the three models. The root-mean-square errors, which indicate the precision of the three prediction models, were 13.06, 13.80, and 13.77. The only model that demonstrated a correlation with the visual parameters was sex (but not age or postmortem interval).

Conclusion: Similar to living subjects, we observed a correlation with age for a number of visual parameters. The parameters that correlate with age depend on whether the site being measured was exposed to sunlight. Age estimation based on visual parameters requires measurement of visual parameters for skin both exposed and not exposed to sunlight.

Download full-text PDF

Source
http://dx.doi.org/10.1111/srt.12683DOI Listing

Publication Analysis

Top Keywords

visual parameters
36
parameters skin
20
parameters
11
visual
9
age estimation
8
estimation based
8
based visual
8
body parts
8
cheek chin
8
brachium thigh
8

Similar Publications

Objective: We aimed to investigate the incidence of delayed-onset neurological deficits (DONDs), DOND-related reoperation rates following adult spinal deformity (ASD) surgery, and efficacy of transverse process hooks (TPHs) at the uppermost instrumented vertebra (UIV) compared to pedicle screws (PSs).

Methods: We included 90 consecutive patients who underwent instrumented fusion from the sacrum to the distal thoracic spine for ASD, with a minimum follow-up of 24 months. Clinical and radiological outcomes were compared between 33 patients in the TPH group and 57 patients in the PS group, using the Scoliosis Research Society-22 Outcomes questionnaire (SRS-22), Medical Outcomes Study Questionnaire Short-Form 36 (SF-36), and various spinal sagittal parameters.

View Article and Find Full Text PDF

Objective: Spinal stenosis is a prevalent condition; however, the optimal surgical treatment for central lumbar stenosis remains controversial. This study compared the clinical outcomes and radiological parameters of 3 surgical.

Methods: unilateral laminectomy bilateral decompression with unilateral biportal endoscopy (ULBD-UBE), conventional subtotal laminectomy (STL), and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF).

View Article and Find Full Text PDF

Live human brain tissues provide unique opportunities for understanding the physiology and pathophysiology of synaptic transmission. Investigations have been limited to anatomy, electrophysiology, and protein localization-while crucial parameters such as synaptic vesicle dynamics were not visualized. Here we utilize zap-and-freeze time-resolved electron microscopy to overcome this hurdle.

View Article and Find Full Text PDF

Unlabelled: Evaluating tissue microstructure and membrane integrity in the living human brain through diffusion-water exchange imaging is challenging due to requirements for a high signal-to-noise ratio and short diffusion times dictated by relatively fast exchange processes. The goal of this work was to demonstrate the feasibility of imaging of tissue micro-geometries and water exchange within the brain gray matter using the state-of-the-art Connectome 2.0 scanner equipped with an ultra-high-performance gradient system (maximum gradient strength=500 mT/m, maximum slew rate=600 T/m/s).

View Article and Find Full Text PDF

A Wireless Health Monitoring System Accomplishing Bimodal Decoupling Based on an "IS"-Shaped Multifunctional Conductive Hydrogel.

Small

January 2025

Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an, 710127, China.

Flexible wearable sensors with bimodal functionality offer substantial value for human health monitoring, as relying on a single indicator is insufficient for capturing comprehensive physiological information. However, bimodal sensors face multiple challenges in practical applications, including mutual interference between various modalities, and integration of excellent mechanical properties, interfacial adhesion, environmental adaptability and biocompatibility. Herein, the multifunctional hydrogel, synthesized through radical grafting and supramolecular self-crosslinking reactions, exhibits excellent thermal sensitivity (TCR = -1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!