A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Semi-quantitative indices of cardiac uptake in patients with suspected cardiac amyloidosis undergoing 99mTc-HMDP scintigraphy. | LitMetric

Background: 99mTc-HMDP scintigraphy has proved its efficacy in non-invasive diagnosis of cardiac amyloidosis (CA) and is currently interpreted according to the Perugini qualitative assessment. Several semi-quantitative indices have been proposed to overcome inherent possible limitations of visual grading. Our aim was to comparatively evaluate six different indices and their diagnostic performance.

Methods: We retrospectively reviewed scintigraphy of 76 patients (53 ATTR, 12 AL, 11 LVH) who underwent diagnostic evaluation at our centre. ROC-curve analysis was performed to identify optimal cut-off and relative diagnostic accuracy of six different indices (of which one was proposed for the first time), both in identifying CA patients and in discriminating patients according to their Perugini score.

Results: Heart/Whole-body ratios proved to be the most accurate (100%) in identifying CA patients. Heart/Pelvis ratio (with soft tissue background correction) offered acceptable accuracy (98%), with the largest area under the curve (AUC) (0.98) in discriminating patients with Perugini ≥ 2. Heart/Contralateral Lung ratio confirmed to be exposed to confounding background noise in case of simultaneous lung uptake. Heart/Skull ratio had the worst performance, with six false-negative patients in ATTR identification.

Conclusion: Heart/Whole-body ratios may be robust and effective semi-quantitative indices for the evaluation of CA by means of scintigraphy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12350-019-01643-wDOI Listing

Publication Analysis

Top Keywords

semi-quantitative indices
12
cardiac amyloidosis
8
99mtc-hmdp scintigraphy
8
indices proposed
8
patients attr
8
identifying patients
8
discriminating patients
8
heart/whole-body ratios
8
patients
7
indices cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!