Background An angiography-based supervised machine learning ( ML ) algorithm was developed to classify lesions as having fractional flow reserve ≤0.80 versus >0.80. Methods and Results With a 4:1 ratio, 1501 patients with 1501 intermediate lesions were randomized into training versus test sets. Between the ostium and 10 mm distal to the target lesion, a series of angiographic lumen diameter measurements along the centerline was plotted. The 24 computed angiographic features based on the diameter plot and 4 clinical features (age, sex, body surface area, and involve segment) were used for ML by XGBoost. The model was independently trained and tested by 2000 bootstrap iterations. External validation with 79 patients was conducted. Including all 28 features, the ML model with 5-fold cross-validation in the 1204 training samples predicted fractional flow reserve ≤0.80 with overall diagnostic accuracy of 78±4% (averaged area under the curve: 0.84±0.03). The 12 high-ranking features selected by scatter search were involved segment; body surface area; distal lumen diameter; minimal lumen diameter; length of a lumen diameter <2.0 mm, <1.5 mm, and <1.25 mm; mean lumen diameter within the worst segment; sex; diameter stenosis; distal 5-mm reference lumen diameter; and length of diameter stenosis >70%. Using those 12 features, the ML predicted fractional flow reserve ≤0.80 in the test set with sensitivity of 84%, specificity of 80%, and overall accuracy of 82% (area under the curve: 0.87). The averaged diagnostic accuracy in bootstrap replicates was 81±1% (averaged area under the curve: 0.87±0.01). External validation showed accuracy of 85% (area under the curve: 0.87). Conclusions Angiography-based ML showed good diagnostic performance in identifying ischemia-producing lesions and reduced the need for pressure wires.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6405668 | PMC |
http://dx.doi.org/10.1161/JAHA.118.011685 | DOI Listing |
Med Phys
December 2024
Department of Echocardiography, Ultrasound Diagnostic Center, The First Hospital of Jilin University, Changchun, China.
Background: Dialysis Access (DA) stenosis impacts hemodialysis efficiency and patient health, necessitating exams for early lesion detection. Ultrasound is widely used due to its non-invasive, cost-effective nature. Assessing all patients in large hemodialysis facilities strains resources and relies on operator expertise.
View Article and Find Full Text PDFPLoS One
December 2024
Department of Surgical and Radiological Sciences, From the University of California-Davis, School of Veterinary Medicine, Davis, Davis, California, United States of America.
Objectives: The primary aim of this study was to evaluate the effects of vasodilator administration on CT angiography (CTA) prostatic artery diameter and peak opacification in dogs with prostatic carcinoma prior to prostatic artery embolization (PAE).
Materials And Methods: A prospective clinical trial was performed. Ten dogs with naturally occurring prostatic carcinoma and no evidence of cardiovascular disease were enrolled.
Pathophysiology
December 2024
Department of Obstetrics and Gynecology, Astana Medical University, Astana 010000, Kazakhstan.
Unlabelled: Histomorphometric measurements of the wall thickness and internal diameter of the macrovessels of the chorionic villi of placentas from pregnancies complicated by preeclampsia or fetal growth restriction in comparison with normotensive pregnancy.
Methods: The research included placentas from singleton pregnancies complicated by preeclampsia and/or fetal growth restriction, women delivered in medical institutions in Karaganda city (Kazakhstan). Placentas were divided into three groups: PE ( = 59), isolated FGR ( = 24), and PE with FGR ( = 41).
Ying Yong Sheng Tai Xue Bao
October 2024
Research Institute of Subtropical Forestry, Chinese Academy of Forestry/Zhejiang Key Laboratory of Forest Genetics and Bree-ding, Hangzhou 311400, China.
To rapidly acquire fiber phenotypic data for wood quality assessment, we used a portable NIR spectro-meter to collect spectral data in 100 individuals of at 18-year-old of 20 different provenances, and simultaneously collected wood cores. Wood basic density and the anatomical structure of wood fiber were measured. The standard normal variate (SNV), orthogonal signal correction (OSC), and multiplicative scatter correction (MSC) methods were used for spectral preprocessing, the competitive adaptive reweighted sampling (CARS) method were used for wavelength selection, and the partial least squares regression (PLSR) model were established.
View Article and Find Full Text PDFCardiol Res
December 2024
Department of Forensic Medicine, Imam Khomeini Hospital, Tehran, Iran.
Background: This study evaluated the safety and efficacy of BioMime sirolimus-eluting stent (SES) system, with an ultra-low strut thickness (65 µm), in real-world all-comers population with coronary artery stenosis (CAD).
Methods: This was a post-marketing, multicenter, single-arm, observational clinical registry among patients undergoing intervention for CAD. Patients were clinically followed up at 1, 9, 12, and 24 months after the index percutaneous coronary intervention.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!