Background Ongoing advancements of coronary computed tomographic angiography (CTA) continue to challenge the role of invasive coronary angiography (ICA) as the gold standard for the evaluation of coronary artery disease (CAD). We sought to investigate the diagnostic accuracy of 320-slice CTA for detecting obstructive CAD in reference to ICA and nuclear myocardial perfusion imaging using single-photon emission computed tomography. Methods For the CORE320 study (Coronary Artery Evaluation Using 320-Row Multidetector Computed Tomography Angiography and Myocardial Perfusion), 381 patients at 16 centers underwent CTA, nuclear myocardial perfusion imaging by single-photon emission computed tomography, and ICA for the evaluation of CAD. Imaging studies were analyzed in blinded core laboratories, and a stenosis of ≥50% by quantitative coronary angiography was considered obstructive, whereas a stress difference score of ≥1 indicated inducible myocardial ischemia. The area under the receiver operating characteristic curve was used to evaluate diagnostic accuracy. Results Of 381 patients, 229 (60%) had obstructive CAD by quantitative coronary angiography. Diagnostic accuracy of CTA on a per-patient analysis revealed an area under the receiver operating characteristic curve of 0.90 (95% CI, 0.87-0.93). Per-vessel and per-segment analysis revealed lower area under the receiver operating characteristic curve of 0.87 (0.84-0.90) and 0.81 (0.78-0.83), respectively. Median radiation dose was lower for CTA versus ICA: 3.16 (interquartile range, 2.82-3.59) versus 11.97 (interquartile range, 7.60-17.8) mSv ( P<0.001). Accuracy for identifying patients with inducible myocardial ischemia by SPECT-MPI was similar for CTA and ICA (area under the receiver operating characteristic curve, 0.68 versus 0.71 by quantitative coronary angiography and 0.68 by visual angiographic assessment; P>0.05). Furthermore, accuracy for identifying patients who subsequently underwent clinically driven coronary revascularization also was similar for CTA (0.76 [0.71-0.81]) and ICA (0.78 [0.74-0.83]; P=0.20). Conclusions Contemporary CTA accurately identifies patients with obstructive CAD by ICA at lower radiation exposure; however, agreement is lower in vessel- and segment-level analyses. Both CTA and ICA perform similarly for predicting clinically driven revascularization and for detecting myocardial ischemia by myocardial perfusion imaging using single-photon emission computed tomography, suggesting that limitations by both CTA and ICA contribute to variability of stenosis quantification. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT00934037.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.118.007720DOI Listing

Publication Analysis

Top Keywords

computed tomography
20
coronary angiography
16
myocardial perfusion
16
diagnostic accuracy
12
obstructive cad
12
perfusion imaging
12
imaging single-photon
12
single-photon emission
12
emission computed
12
area receiver
12

Similar Publications

The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.

View Article and Find Full Text PDF

A rare complication of a thoracic wound: the pneumopericardium?

Forensic Sci Med Pathol

January 2025

LaTIM, Inserm UMR 1101, 22 Avenue Camille-Desmoulins, CS 93837, Brest cedex, 29238, France.

Pneumopericardium (PPC) is defined by the presence of gas in the pericardial cavity, often leading to cardiac tamponade and a high mortality rate. This report describes a case involving a 33-year-old man found deceased a few meters from a knife, his clothes intact, with no resuscitation attempt made. A knotted scarf was tightly fastened around his neck, without ligature mark.

View Article and Find Full Text PDF

Background: The impact of fatty liver disease on lumbar bone mineral density (BMD) represents an intriguing area of study, particularly in light of established research linking obesity to bone metabolism. However, there remains limited investigation into the correlation between quantifying liver fat content (LFC) and lumbar BMD among overweight and obese populations, particularly within the Chinese demographic. This study aims to accurately quantify LFC and investigate its association with lumbar BMD in overweight or obese individuals.

View Article and Find Full Text PDF

Background: As survival following PD improved, long-term complications have emerged as an issue in current era. Pancreaticojejunostomy stenosis is the common long-term sequel after PD but rarely addressed. This study aimed to investigate the benefit of pancreatic duct stent in reducing PJ stenosis after PD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!