The circulating-tumor-cell (CTC) specific aptamer is believed to be a power recognition factor to realize clinical CTC assay. However, the limited sensing range is still one of the challenges in its real application. The porous-graphene-oxide (PGO) enhanced aptamer specific CTC sensing interface is studied on the platform of light-addressable-potentiometric-sensor (LAPS) to provide a clinical available method for CTC detection. The underlying mechanism of this sensing interface on LAPS is modeled and simulated. It is confirmed to be a promising candidate for CTC assay by the linear responding for 5-5000 spiked cells, as well as the satisfactory sensitivity for clinical samples.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.8b21101DOI Listing

Publication Analysis

Top Keywords

sensing interface
12
enhanced aptamer
8
aptamer specific
8
ctc assay
8
ctc
5
porous graphene
4
graphene oxide
4
oxide enhanced
4
specific circulating-tumor-cell
4
sensing
4

Similar Publications

Ultrathin atomic layer deposited ceria films (< 20 nm) are capable of H2 heterolytic activation at room temperature, undergoing a significant reduction regardless of the absolute pressure, as measured under in-situ conditions by near ambient pressure X-ray photoelectron spectroscopy. ALD-ceria can gradually reduce as a function of H2 concentration under H2/O2 environments, especially for diluted mixtures below 10%. At room temperature, this reduction is limited to the surface region, where the hydroxylation of the ceria surface induces a charge transfer towards the ceria matrix, reducing Ce4+ cations to Ce3+.

View Article and Find Full Text PDF

Ultra-Fast Moisture Sensor for Respiratory Cycle Monitoring and Non-Contact Sensing Applications.

Adv Mater

January 2025

Henry Royce Institute and Photon Science Institute, Department of Electrical and Electronic Engineering, The University of Manchester, Oxford Road, Manchester, M13 9PL, UK.

As human-machine interface hardware advances, better sensors are required to detect signals from different stimuli. Among numerous technologies, humidity sensors are critical for applications across different sectors, including environmental monitoring, food production, agriculture, and healthcare. Current humidity sensors rely on materials that absorb moisture, which can take some time to equilibrate with the surrounding environment, thus slowing their temporal response and limiting their applications.

View Article and Find Full Text PDF

In recent years, the utilization of motor imagery (MI) signals derived from electroencephalography (EEG) has shown promising applications in controlling various devices such as wheelchairs, assistive technologies, and driverless vehicles. However, decoding EEG signals poses significant challenges due to their complexity, dynamic nature, and low signal-to-noise ratio (SNR). Traditional EEG pattern recognition algorithms typically involve two key steps: feature extraction and feature classification, both crucial for accurate operation.

View Article and Find Full Text PDF

Soil moisture is a key parameter for the exchange of substance and energy at the land-air interface, timely and accurate acquisition of soil moisture is of great significance for drought monitoring, water resource management, and crop yield estimation. Synthetic aperture radar (SAR) is sensitive to soil moisture, but the effects of vegetation on SAR signals poses challenges for soil moisture retrieval in areas covered with vegetation. In this study, based on Sentinel-1 SAR and Sentinel-2 optical remote sensing data, a coupling approach was employed to retrieval surface soil moisture over dense vegetated areas.

View Article and Find Full Text PDF

Background: Clinical guideline development preferentially relies on evidence from randomized controlled trials (RCTs). RCTs are gold-standard methods to evaluate the efficacy of treatments with the highest internal validity but limited external validity, in the sense that their findings may not always be applicable to or generalizable to clinical populations or population characteristics. The external validity of RCTs for the clinical population is constrained by the lack of tailored epidemiological data analysis designed for this purpose due to data governance, consistency of disease or condition definitions, and reduplicated effort in analysis code.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!