The effect of doubling the immersion fluid (eluate) volume on antibiotic concentrations and on mechanical stability from vancomycin and gentamicin loaded bone cements was investigated in vitro. Antibiotic loaded bone cements containing premixed 1.34% gentamicin antibiotic concentration in the cement powder (wt), premixed 1.19% gentamicin wt and 4.76% vancomycin wt and premixed 1.17% wt gentamicin additionally manually blended with 4.68% wt vancomycin were tested. Six specimens per group were immersed in 4 ml and 8 ml for 6 weeks while the eluate was exchanged every 24 h. The antibiotic concentrations were repeatedly measured. Then the specimens were tested for compressive strength. Doubling the eluate volume significantly decreased gentamicin and vancomycin concentrations from 6 h and 24 h on, except for the gentamicin concentration of the additionally manually blended formulation after 3 weeks. The additionally manually blended vancomycin formulation produced significantly higher gentamicin concentrations in 8 ml compared to the other formulations. The reduction ratios of the vancomycin concentrations were significantly smaller than the reduction ratios of the gentamicin concentrations for the manually blended vancomycin formulation. Vancomycin containing formulations showed significantly lower compressive strengths than the vancomycin free formulation after immersion. Doubling the eluate volume lead to significant compressive strength reduction of the vancomycin containing formulations. Eluate volume change influences antibiotic elution dependent on the antibiotic combination and loading technique. The reducing effect is higher on vancomycin than on gentamicin elution. Compressive strength of gentamicin/vancomycin loaded bone cements after immersion is eluate volume dependent.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10856-019-6229-7 | DOI Listing |
Talanta
March 2025
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic. Electronic address:
An off-the-shelf Agilent 7100 capillary electrophoresis (CE) instrument was employed for the automated processing and analysis of dried blood spots (DBSs) collected by Capitainer®B volumetric devices. Solutions for DBS elutions were transferred directly into CE vials through a separation capillary by the application of an auxiliary nitrogen gas connected to the external pressure line of the CE instrument. This allowed for liquid handling at pressures up to 15 bar and enabled the use of a single capillary for rapid DBS processing and efficient CE separations.
View Article and Find Full Text PDFAnal Chim Acta
November 2024
University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, Institute of Analytical Chemistry, Muthgasse 18, 1190, Wien, Austria. Electronic address:
Background: Solid phase extraction (SPE) is a standard sample preparation technique in HPLC workflows. Inline cartridges are high-performance alternatives to manual or robotic systems but at long term, they suffer from irreversible sorption of matrix components and sorbent compaction. Bead injection (BI) is a niche fluidic technique that allows renewing a sorbent bed through the manipulation of its suspension.
View Article and Find Full Text PDFTalanta
December 2024
Shenyang Key Laboratory of Medical Molecular Theranostic Probes in School of Pharmacy, Shenyang Medical College, 146 Huanghe North Avenue, Shenyang, 110034, China. Electronic address:
Development of fresh solid phase extractant is critical for selective separation and purification of special proteins. Herein, we demonstrated a recombinant Staphylococcal Protein G (rSPG) with a His-tag modified the novel single-metal organic framework (rSPG@Ni-MOF-74). The proposed solid-phase extraction material possessed a uniform spindle-shaped structure, large surface area (709.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
August 2024
Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Kraków, Poland.
An automated flow analysis-solid phase extraction (FA-SPE) system and methodology of ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) analysis were developed for the determination of selected antiviral drugs (acyclovir, amantadine, rimantadine, and oseltamivir) in water samples. The proposed FA-SPE approach enables the integration of various extraction stages and elimination of the sample evaporation step and offers individual customisation of SPE parameters, inter alia sample, and eluate flow rate and volume. Using the developed FA-SPE procedure, e.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
July 2024
Institute of Health Inspection and Testing, Fujian Center for Disease Control and Prevention, Fuzhou, China.
This study presents a method based on acid transesterification and the purification by solid-phase extraction (SPE) coupled with gas chromatography-tandem mass spectrometry for quantifying 3- and 2-monochloropropanediol esters (3-MCPDE, 2-MCPDE) and glycidyl esters (GE) in nutritional foods. The fat was extracted by liquid-liquid extraction with petroleum ether and diethyl ether after the sample was hydrolysed with ammonia. Then the extract was purified by a SPE cartridge filled with the aminopropyl sorbents.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!