Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
High-rise deep street canyons usually experience poor ventilation and large vehicular pollutant exposure to residents in near-road buildings. Investigations are still required to clarify the flow and dispersion mechanisms in deep street canyons and explore techniques to reduce such large pollutant exposure. By conducting computational fluid dynamics (CFD) simulations validated by wind tunnel data and scale-model outdoor field measurements, we investigate the integrated impacts of aspect ratios, first-floor and second-floor elevated building designs, viaduct settings, height variations and wind catchers on the flow, personal intake fraction (P_IF) of CO (carbon dioxide) and its spatial mean value 〈P_IF〉 in two-dimensional (2D) street canyons. Results show that cases with H/W = 5 experience two counter-rotating vortices, much poorer ventilation and 1-2 orders larger 〈P_IF〉 (43.6-120.8 ppm) than H/W = 1 and 3 (3.8-4.3 and 5.6-5.8 ppm). Moreover, in cases with H/W = 5 the height variation results in three vertically-aligned vortices and much weaker wind, subsequently produces greater 〈P_IF〉 (1402-2047 ppm). To reduce 〈P_IF〉 with H/W = 5, various urban designs are evaluated. The first-floor elevated building design creates more effective ventilation pathways than the second-floor elevated type does and reduces 〈P_IF〉 at H/W = 5 by five orders (1402 to ~0.01 ppm) or two orders (43.6 to ~0.1 ppm) in cases with or without the height variation. However, such reductions at H/W = 1 and 3 are only 76.8%-81.4% and 22.4%-36.2% respectively. Wind catchers destroy the multi-vortex flow pattern as H/W = 5, produce a contra-clockwise main vortex and reduce 〈P_IF〉 by 1-2 orders for cases with or without the height variation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2018.10.333 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!