Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: The aim of this study was to compare force loss due to friction (Fr) during simulated canine retraction using different archwire dimensions and materials between conventional and new self-ligating brackets.
Methods: The tested brackets were (1) conventional brackets (Victory series, GAC twin and FLI twin), (2) self-ligating brackets (Damon-Q, FLI-SL, new/improved FLI-SL (I FLI-SL), SPEED, GAC innovation (R) and Ortho Classic) and (3) a low-friction bracket (Synergy). All brackets had a 0.022″ slot size. The tested archwires were stainless steel (0.018″; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″); nickel titanium (NiTi; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″) and titanium molybdenum alloy (TMA; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″). Canine retraction was experimentally simulated in a biomechanical set-up using a NiTi coil spring that delivered a force of 1 N. The simulated retraction path was up to 4 mm. Force loss due to friction was compared between groups using the Welch t‑test.
Results: Force loss due to friction increased with increasing archwire size. Also, TMA showed the highest and stainless steel the lowest force loss due to friction. FLI-SL brackets showed the lowest Fr (31%) and Ortho Classic showed the highest (67%).
Conclusions: Increasing wire size generally showed increasing force loss due to friction. FLI-SL brackets showed the lowest, while Ortho Classic showed the highest friction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00056-019-00168-8 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!