A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Shorter cryoballoon applications times do effect efficacy but result in less phrenic nerve injury: Results of the randomized 123 study. | LitMetric

Background: The second-generation cryoballoon significantly improves outcome of pulmonary vein isolation (PVI) but may cause more complications than the first generation. Currently, no consensus regarding optimal cryoballoon application time exists. The 123-study aimed to assess the minimal cryoballoon application duration necessary to achieve PVI (primary endpoint) and the effect of application duration on prevention of phrenic nerve injury (PNI).

Methods: Patients <75 years of age with paroxysmal atrial fibrillation, normal PV anatomy, and left atrial size <40 cc/m² or <50 mm were randomized to two applications of different duration: "short," "medium," or "long." A total of 222 patients were enrolled, 74 per group.

Results: Duration per application was 105 (101-108), 164 (160-168), and 224 (219-226) s and isolation was achieved in 79, 89, and 90% (P < 0.001) of the PVs after two applications in groups short, medium, and long, respectively. Only for the left PVs, the success rate of the short group was significantly less compared to the medium- and long-duration groups (P < 0.001). PNI during the procedure occurred in 19 PVs (6.5%) in the medium and in 20 PVs (6.8%) in the long duration groups compared to only five PVs (1.7%) in the short duration group (P < 0.001).

Conclusions: Short cryoballoon ablation application times, less than 2 min, did affect the success for the left PVs but not for the right PVs and resulted in less PNI. A PV tailored approach with shorter application times for the right PVs might be advocated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6850154PMC
http://dx.doi.org/10.1111/pace.13626DOI Listing

Publication Analysis

Top Keywords

phrenic nerve
8
nerve injury
8
cryoballoon application
8
application duration
8
shorter cryoballoon
4
cryoballoon applications
4
applications times
4
times efficacy
4
efficacy result
4
result phrenic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!