Purpose: High dose rate brachytherapy applies intense and destructive radiation. A treatment plan defines radiation source dwell positions to avoid irradiating healthy tissue. The study discusses methods to quantify any positional changes of source locations along the various treatment sessions.

Methods: Electromagnetic tracking (EMT) localizes the radiation source during the treatment sessions. But in each session the relative position of the patient relative to the filed generator is changed. Hence, the measured dwell point sets need to be registered onto each other to render them comparable. Two point set registration techniques are compared: a probabilistic method called coherent point drift (CPD) and a multidimensional scaling (MDS) technique.

Results: Both enable using EMT without external registration and achieve very similar results with respect to dwell position determination of the radiation source. Still MDS achieves smaller grand average deviations (CPD-rPSR: MD = 2.55 mm, MDS-PSR: MD = 2.15 mm) between subsequent dwell position determinations, which also show less variance (CPD-rPSR: IQR = 4 mm, MDS-PSR: IQR = 3 mm). Furthermore, MDS is not based on approximations and does not need an iterative procedure to track sensor positions inside the implanted catheters.

Conclusion: Although both methods achieve similar results, MDS is to be preferred over rigid CPD while nonrigid CPD is unsuitable as it does not preserve topology.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13443DOI Listing

Publication Analysis

Top Keywords

radiation source
12
point set
8
set registration
8
electromagnetic tracking
8
dwell position
8
technical note
4
note comparison
4
point
4
comparison point
4
registration methods
4

Similar Publications

Purpose: It is not known whether temporal changes in childhood cancer therapy have reduced risk of subsequent malignant neoplasms (SMNs) of the central nervous system (CNS), a frequently fatal late effect of cancer therapy.

Methods: Five-year survivors of primary childhood cancers diagnosed between 1970-1999 in the Childhood Cancer Survivor Study with a subsequent CNS SMN were identified. Cumulative incidence rates and standardized incidence ratios (SIR) were compared among survivors diagnosed between 1970-1979 (N = 6223), 1980-1989 (N = 9680), and 1990-1999 (N = 8999).

View Article and Find Full Text PDF

Objectives: To survey kilovoltage (kV) radiotherapy in the UK, updating a 2016 study, focussing on radiotherapy physics, including equipment quality control (QC) and radiation dosimetry, with information on installed equipment and clinical activity.

Methods: All UK radiotherapy physics departments (n = 68) were invited to complete a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical activity, QC testing and radiation dosimetry processes were undertaken.

View Article and Find Full Text PDF

Exploring offshore particle motion soundscapes.

J Acoust Soc Am

January 2025

Center for Acoustics Research and Education, University of New Hampshire, Durham, New Hampshire 03823, USA.

Fishes and aquatic invertebrates utilize acoustic particle motion for hearing, and some additionally detect sound pressure. Yet, few underwater soundscapes studies report particle motion, which is often assumed to scale predictably with pressure in offshore habitats. This relationship does not always exist for low frequencies or near reflective boundaries.

View Article and Find Full Text PDF

Assessment of the Performance of the Dose Calibrator Used in Radioactivity Measurement.

Indian J Nucl Med

November 2024

Center for Research and Production of Radioisotopes, Dalat Nuclear Research Institute, Vietnam Atomic Energy Institute (VINATOM), Da Lat City, Lam Dong Province, Vietnam.

Aims: This study aimed to evaluate the principal technical characteristics of a well-type gas-filled ionization chamber dose calibrator used in measuring radiopharmaceutical activity, namely accuracy, repeatability, and linearity. Furthermore, this work also explored the correlation between the device's response and the position and volume of the radiopharmaceutical I-131.

Materials And Methods: Experimental measurements were conducted on the ATOMLAB 500 dose calibrator using NIST traceable Cs-137 source to determine the accuracy and repeatability.

View Article and Find Full Text PDF

Herein, highly fluorescent sulfur and nitrogen co-doped carbon dots (N, S-CDs) had been employed as a fluorescent probe to analyze Cu in drinking water. The biogenic creatinine is known to form a stable complex with Cu; hence, it was rationally selected as a bioinspired nitrogen substrate for the first time to enhance N, S-CDs selectivity towards Cu. Moreover, the literature was surveyed to guide the selection of sulfur and carbon sources to optimize N, S-CDs quantum yield (QY), so thiourea and disodium edetate are co-carbonized with biogenic creatinine at 270°C for 40 min and characterized using different techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!