A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical Simulation Based on Individual Voxel Phantoms for a Sophisticated Evaluation of Internal Doses Mainly From 131I in Highly Exposed Workers Involved in the TEPCO Fukushima Daiichi NPP Accident. | LitMetric

AI Article Synopsis

  • * Researchers conducted numerical simulations using individual voxel phantoms based on MRI scans of six of the seven workers, focusing on their thyroid sizes which were generally smaller than standard reference values.
  • * The study found that individual thyroid size significantly impacts dose estimation, with results showing absorbed doses could vary widely, and confirmed the accuracy of direct thyroid measurements from the National Institute for Radiological Sciences.

Article Abstract

As a response to the Tokyo Electric Power Company's Fukushima Daiichi nuclear power plant accident in 2011, seven TEPCO workers whose exposure doses were expected to be >250 mSv (a tentative dose limit stipulated by the Japanese central authority) attended Japan's National Institute for Radiological Sciences for additional internal dose measurements. The National Institute for Radiological Sciences examination revealed that these workers' internal doses came mainly from their intake of the radionuclide I during emergency operations. In this study, we performed numerical simulations based on individual volume-pixel (voxel) phantoms of six of the seven workers for a more sophisticated evaluation of their internal doses, taking into account the individual thyroid size and other specific parameters. The voxel phantoms were created from magnetic resonance imaging scan images. As a result, the individual thyroid volumes ranged from 6.5 to 28.2 cm and were considerably smaller than the reference value (~20 cm) adopted in the International Commission on Radiation Protection's dosimetric model for four of the six subjects. Compared to the original estimates of the thyroid absorbed dose, our preliminary evaluation revealed values that were increased by approximately 3-fold or decreased by 30% at maximum. A wide difference in the individual thyroid size would be one of the significant modifiers in the current dose estimation of subjects of the ongoing epidemiological study project. The present simulations also provided evidence that the direct thyroid measurements by the National Institute for Radiological Sciences to determine the workers' I thyroid contents were sufficiently accurate.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HP.0000000000000995DOI Listing

Publication Analysis

Top Keywords

voxel phantoms
12
internal doses
12
national institute
12
institute radiological
12
radiological sciences
12
individual thyroid
12
based individual
8
sophisticated evaluation
8
evaluation internal
8
fukushima daiichi
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!