Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a versatile tool to obtain hemodynamic information and anatomic information simultaneously. The wall shear stress (WSS), a force exerted on a vessel wall in parallel, is one of the hemodynamic parameters available with 4D flow MRI and is thought to play an important role in clinical applications such as assessing the development of atherosclerosis. Nevertheless, the accuracy of WSS obtained with 4D flow MRI is rarely evaluated or reported in literature, especially in the in vivo studies. We propose a novel and facile criterion called Reynolds resolution to assess the accuracy of WSS estimation in 4D flow MRI studies. Reynolds resolution consists of a spatial resolution, encoding velocity, kinematic viscosity of a working fluid, and signal-to-noise ratio, which are readily accessible information in 4D flow MRI measurements. We explored the relationship between Reynolds resolution and the WSS error. To include diverse and extensive cases, we measured three circular tubing flows with a diameter of 40, 8, and 2 mm. The 40 mm tubing flow was measured by 3 Tesla (T) human MR scanner with a knee coil and spatial resolution of 0.5 mm. The 8 and 2 mm tubing flows were both measured by 4.7 T MR scanner, but the scans were performed with a conventional birdcage coil (8 mm tubing) and a custom-made solenoid coil (2 mm tubing), respectively. The spatial resolution was varied from 0.2, 0.4 or 0.8 mm for the 8 mm tubing flow, but was fixed at 0.090 mm for 2 mm tubing flow. In addition, the near-wall velocity gradient, required to be determined prior to the WSS, was calculated using two methods; these included assuming a linear velocity profile or quadratic velocity profile near wall. The accuracy of WSS obtained using each method and tubing flow was evaluated against the theoretical WSS value. As a result, we found that Reynolds resolution is in logarithmic relation to the WSS error.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.media.2019.01.009 | DOI Listing |
PLoS One
January 2025
Department of Neurosurgery, Osaka University Graduate School of Medicine, Osaka, Japan.
Background: Glioblastoma is characterized by neovascularization and diffuse infiltration into the adjacent tissue. T2*-based dynamic susceptibility contrast (DSC) MR perfusion images provide useful measurements of the biomarkers associated with tumor perfusion. This study aimed to distinguish infiltrating tumors from vasogenic edema in glioblastomas using DSC-MR perfusion images.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Cardiovascular Center, St. Luke's International Hospital, Tokyo, Japan.
Right ventricular (RV) dysfunction after biventricular repair is critical in most adults with congenital heart disease (ACHD). Conventional 2D magnetic resonance imaging (MRI) measurement is considered as a 'gold standard' for RV evaluation; however, addition information on ACHD after biventricular repair is sometimes required. The reasons why adjunctive information is required is as follows: (I) to evaluate the severity of cardiac burden in symptomatic patients with normal RV size and ejection fraction (EF), (II) to determine the optimal timing of invasive treatments in asymptomatic ones, and (III) to detect proactively a potential cardiac burden leading to ventricular deterioration, from a fluid dynamics perspective.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Operational Research Center in Healthcare, Near East University, Nicosia, Turkey.
Background: Cardiovascular diseases (CVDs) continue to be the world's greatest cause of death. To evaluate heart function and diagnose coronary artery disease (CAD), myocardial perfusion imaging (MPI) has become essential. Artificial intelligence (AI) methods have been incorporated into diagnostic methods such as MPI to improve patient outcomes in recent years.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
J Korean Neurosurg Soc
January 2025
Department of Neurosurgery, Kyung Hee University Hospital, Kyung Hee University College of Medicine, Seoul, Korea.
Objective: The leptomeningeal ivy sign is a distinctive finding of moyamoya disease (MMD), characterized by a linear high signal intensity along the cortical sulci on contrast-enhanced T1 magnetic resonance imaging (MRI) and fluid-attenuated inversion-recovery MRI. We recently identified a similar linear enhancement along the cortical sulci using gadolinium-enhanced vessel wall MRI (VWMR) in patients with MMD. The aim of this study was to introduce the concept of the "VWMR ivy sign (VIS)".
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!