A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a simple numerical model for trabecular bone structures. | LitMetric

Purpose: Advances in additive manufacturing processes are enabling the fabrication of surrogate bone structures for applications including use in high-resolution anthropomorphic phantoms. In this research, a simple numerical model is proposed that enables the generation of microarchitecture with similar statistical distribution to trabecular bone.

Methods: A human humerus, radius, ulna, and several vertebrae were scanned on the Imaging and Medical beamline at the Australian Synchrotron and the proposed numerical model was developed through the definition of two complex functions that encode the trabecular thickness and position-dependant spacing to generate volumetric surrogate trabecular structures. The structures reproduced those observed at 19 separate axial locations through the experimental bone volumes. The applicability of the model when incorporating a two-material approximation to absorption- and phase-contrast CT was also investigated through simulation.

Results: The synthetic structures, when compared with the real trabecular microarchitecture, yielded an average mean thickness error of 2 μm, and a mean difference in standard deviation of 33 μm for the humerus, 24 μm for the ulna and radius, and 15 μm for the vertebrae. Simulated absorption- and propagation-based phase contrast CT projection data were generated and reconstructed using the derived mathematical simplifications from the two-material approximation, and the phase-contrast effects were successfully demonstrated.

Conclusions: The presented model reproduced trabecular distributions that could be used to generate phantoms for quality assurance and validation processes. The implication of utilizing a two-material approximation results in simplification of the additive manufacturing process and the generation of synthetic data that could be used for training of machine learning applications.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13435DOI Listing

Publication Analysis

Top Keywords

numerical model
12
two-material approximation
12
simple numerical
8
bone structures
8
additive manufacturing
8
trabecular
6
model
5
structures
5
development simple
4
model trabecular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!