A hands-on learning module was implemented at Marquette University in 2012 to teach biomedical engineering students about basic manufacturing processes, lean manufacturing principles, and design for manufacturability. It incorporates active and student-centered learning as part of in-class assembly line simulations. Since then, it has evolved from three class periods to five. The module begins with two classroom presentations on manufacturing operations and electronics design, assembly, and testing. Students then participate in an in-class assembly line simulation exercise where they build and test an actual product per written work instructions. They reflect on this experience, and suggest design and process changes to improve the assembly line process and quality, save time, and reduce cost and waste. At the end of the module students implement their suggested design and process improvements and repeat the exercise to determine the impact of their improvements. They learn of the importance of Design for Manufacturability, well-written work instructions, process design, and designing a product not only for the end user, but also for the assemblers and inspectors. Details of the module, and its implementation and assessment are presented along with student feedback and faculty observations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6364985PMC

Publication Analysis

Top Keywords

design manufacturability
12
student-centered learning
8
in-class assembly
8
work instructions
8
design process
8
design
7
learning approach
4
approach design
4
manufacturability meeting
4
meeting often-forgotten
4

Similar Publications

A synchronized event-cue feedback loop integrating a 3D printed wearable flexible sensor-tactor platform.

Biosens Bioelectron

January 2025

Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:

Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.

View Article and Find Full Text PDF

Purpose: To investigate the impact of the distance from the most-anterior surface of the optic to the principal object plane (POP) and from the foremost haptic to the principal object plane (H-POP) on the intraocular lens (IOL) power calculation.

Setting: A tertiary hospital.

Design: Optical simulation and retrospective cross-sectional study.

View Article and Find Full Text PDF

Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.

Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.

View Article and Find Full Text PDF

A cross-sectional study on improving clinical efficiency through centralized digital impression.

Hua Xi Kou Qiang Yi Xue Za Zhi

February 2025

Center of Stomatology, Peking University Shenzhen Hospital, Shenzhen 518036, China.

Objectives: This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.

Methods: The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.

View Article and Find Full Text PDF

Gaseous Synergistic Self-Assembly and Arraying to Develop Bio-Organic Photocapacitors for Neural Photostimulation.

Adv Sci (Weinh)

January 2025

State Key Laboratory of Fluid Power and Mechatronic Systems, Key Laboratory of Advanced Manufacturing Technology of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310058, China.

Bioinspired supramolecular architectonics is attracting increasing interest due to their flexible organization and multifunctionality. However, state-of-the-art bioinspired architectonics generally take place in solvent-based circumstance, thus leading to achieving precise control over the self-assembly remains challenging. Moreover, the intrinsic difficulty of ordering the bio-organic self-assemblies into stable large-scale arrays in the liquid environment for engineering devices severely restricts their extensive applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!