Item reduction of the patient-rated wrist evaluation using decision tree modelling.

Disabil Rehabil

Department of Plastic, Reconstructive and Hand Surgery, Erasmus MC, Rotterdam, the Netherlands.

Published: September 2020

The aim of this study is to assess the viability of a decision tree version of an often used questionnaire to measure wrist pain and disability, the Patient Rated Wrist Evaluation.: Patient Rated Wrist Evaluation scores were collected from a cohort of 10394 patients who are part of a routine outcome measurement system. A decision tree version of the Patient Rated Wrist Evaluation (PRWE) was created. The intraclass correlation was used to evaluate the inter-version reliability between the original PRWE and the decision tree version.: The decision tree reduced the number of questions from 5 to 3 for the pain subscale, and from 10 to 3 for the disability subscale. The intraclass correlation between the original PRWE and the decision tree version was 0.97. The mean difference between the Patient Rated Wrist Evaluation and the decision tree Patient Rated Wrist Evaluation total sumscore was 0.35 (95% CI -9.92-10.62).: We found that the decision tree was successful at reducing the items of the Patient Rated Wrist Evaluation from fifteen to only six questions with very high similarity to the scores of the full questionnaire.Implications for rehabilitationThe Patient Rated Wrist Evaluation can reliably be used with 6 instead of 15 questions.Decision trees are useful statistical tools to shorten lengthy questionnaires, especially when large amounts of data are available.Having a shortened Patient Rated Wrist Evaluation saves patients and clinicians time in answering this specific questionnaire.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09638288.2019.1566407DOI Listing

Publication Analysis

Top Keywords

wrist evaluation
36
decision tree
32
patient rated
32
rated wrist
32
tree version
16
wrist
10
evaluation
9
decision
8
evaluation decision
8
tree
8

Similar Publications

Evaluating the performance of a new ergonomic laparoscopic needle holder for intracorporeal suturing.

PLoS One

January 2025

Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.

In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip.

View Article and Find Full Text PDF

Background: Complicated wrist amputation caused by severe trauma poses a real challenge for orthopedic and hand surgeons. This study aimed to evaluate a procedure of ulnoradial-metacarpal reconstruction as a rescue option in this challenging situation.

Methods: In total, 12 patients with complicated wrist amputation induced by serious injury were selected from 2015 to 2020 and followed up for 1∼6 years at a level 1 trauma center.

View Article and Find Full Text PDF

This study evaluates the outcomes of arthroscopic triangular fibrocartilage complex (TFCC) foveal reattachment using an inside-out suture passing through the TFCC at specific ulnocarpal anatomical landmarks to grasp the radioulnar ligaments. Thirty-eight patients with a mean age of 36 years (range 19-54), diagnosed with TFCC injury with distal radioulnar joint (DRUJ) instability, underwent arthroscopic inside-out TFCC foveal reattachment using designated suture sites. At a mean follow-up of 32 months (range 26-44), pain score, range of motion, grip strength, Disabilities of the Arm, Shoulder and Hand (DASH) score, and Modified Mayo Wrist Score all showed significant improvement after surgery.

View Article and Find Full Text PDF

Objective: This study aimed to assess reachable workspace (RWS) in patients post-osteosynthesis of shoulder, elbow, or wrist fractures and explore correlations with self-reported function and kinesiophobia.

Design: An observational case-control study compared patients with fractures to a control group, utilizing questionnaires and 3D kinematic data.

Participants: The sample included 66 individuals who had undergone osteosynthesis: 21 with shoulder fractures, 10 with elbow fractures, and 22 with wrist fractures.

View Article and Find Full Text PDF

Introduction Human errors are a leading cause of disability and death among hospitalized patients. Globally, various strategies have been employed to reduce errors and to improve the quality of patient care. One such novel effort never attempted before is the Health-QUEST (Quality Upgradation Enabled by Space Technology) initiative which aims at translating the best quality and safety practices of the Indian Space Research Organization (ISRO) into the realm of emergency care.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!