Objectives: To investigate the relationship of the irradiance-beam-profile areas from six different light-curing units (LCUs) with the degree of conversion (DC), microhardness (KH), and cross-link density (CLD) throughout a resin-based composite (RBC) cured at two clinically relevant distances, and to explore the correlations among them.
Materials And Methods: A mapping approach was used to measure DC using micro-Raman spectroscopy, KH using a Knoop indentor on a hardness tester, and %KH reduction after ethanol exposure, as an indicator for CLD within a nano-hybrid RBC increment (n = 3) at various depths. These sample composites were cured from two distances while maintaining the radiant exposure, using six different light-curing units: one quartz-tungsten-halogen; two single and three multiple-emission-peak light-emitting-diode units. Irradiance beam profiles were generated for each LCU at both distances, and localized irradiance values were calculated. Points across each depth were analyzed using repeated measures ANOVA. Correlations across multiple specimen locations and associations between beam uniformity corresponding with polymerization measurements were calculated using linear mixed models and Pearson correlation coefficients.
Results: Significant non-uniform polymerization patterns occurred within the specimens at various locations and depths. At 2-mm curing distance, the localized DC = 52.7-76.8%, KH = 39.0-66.7 kg/mm, and %KH reduction = 26.7-57.9%. At 8-mm curing distance, the localized DC = 50.4-78.6%, KH = 40.3-73.7 kg/mm, and %KH reduction = 28.2-56.8%. The localized irradiance values were weakly correlated with the corresponding DC, KH, and %KH reduction, with only a few significant correlations (p < 0.05).
Conclusions: Although significant differences were observed at each depth within the specimens, the localized irradiance values for all LCUs did not reflect the polymerization pattern and did not seem to have a major influence on polymerization patterns within the RBC, regardless of the curing distance.
Clinical Relevance: Commonly used LCUs do not produce uniform polymerization regardless of the curing distance, which may contribute to the risk of RBC fracture.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00784-019-02831-1 | DOI Listing |
BMC Oral Health
January 2025
Faculty of Dentistry, Thammasat University, Pathum Thani, 12120, Thailand.
Background: This study aimed to develop ion-releasing and antibacterial resin-based dental sealants comprising 3 to 6 wt% monocalcium phosphate monohydrate (MCPM, M), 3 to 6 wt% bioactive glass (BAG, B), and 3 to 6 wt% polylysine (PLS, P). The physical properties, mechanical performance, cytotoxicity, and inhibition of S. mutans biofilm by these materials were subsequently evaluated.
View Article and Find Full Text PDFJ Esthet Restor Dent
January 2025
Operative Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Objective: To investigate the effect of cervical margin relocation with four different injectable restorative materials on the fracture resistance of molars receiving mesio-occluso-distal CAD/CAM nanoceramic onlay restorations.
Materials And Methods: One hundred and five sound mandibular molars received a standardized mesio-occluso-distal onlay preparation, with cervical margins located 2 mm apical to the cemento-enamel junction. The molars were randomly allocated into five groups (n = 21) according to the cervical relocating materials used: Group I had no cervical margin relocation; Group II used a highly viscous glass ionomer; Group III used a highly-filled injectable resin composite; Group IV used a resin-modified glass ionomer; and Group V used a bioactive ionic resin.
J Coll Physicians Surg Pak
January 2025
Department of Stomatology, The Second People's Hospital of Hefei and Hefei Hospital Affiliated to Anhui Medical University, Hefei, Anhui, China.
Objective: To investigate the effects of bulk-fill, resin-based composite types (high or low viscosity) on the internal adaptation of Class V restorations.
Study Design: Experimental study. Place and Duration of the Study: Hefei Stomatological Hospital, Hefei, China, from October 2022 to December 2023.
Clin Cosmet Investig Dent
January 2025
College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
Aim: This study evaluated the color stability and surface roughness of two universal-shade compared to two nanohybrid composites after staining and external bleaching with 40% hydrogen peroxide.
Methods: Two universal shade resin-based composites and two nanohybrid composites were tested. Twenty disc-shaped specimens from each material were fabricated and divided into two subgroups: one group was stained and bleached (staining group) and the other received bleaching treatment only (control group).
Clin Oral Investig
January 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology School & Hospital of Stomatology, Wuhan University, Wuhan, China.
Objectives: To summarize and analyze existing evidence regarding the clinical performance of high-viscosity glass-ionomer-based materials (HVGIs) and bulk-fill resin-based composites (BFs) in patients with occlusal or proximal cavities in permanent teeth.
Materials And Methods: A literature search was conducted using PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), Embase, Scopus, and Web of Science (WOS) (last update: April 19th, 2024). Randomized control trials (RCTs), retrospective and prospective comparative cohorts were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!