The onset of self-absorption of laser-induced plasma poses a problem for converting emission line intensities to concentrations, which is one of the main bottlenecks in quantitative laser-induced breakdown spectroscopy (LIBS) measurements. In this paper, the effects of atmosphere and laser fluence on self-absorption reduction of the plasma induced on tungsten-copper alloy target were investigated with nanosecond infrared (1064 nm) laser pulse over a range of 2.9 to 18.2 J/cm. The time-resolved features of self-absorption, and temperature and electron density of the plasma were characterized in atmospheric air and argon, respectively. The experimental results show the effect of self-absorption can be significantly reduced by increasing the laser pulse energy. The argon atmosphere is more helpful for self-absorption reduction. The time-resolved diagnostics of emission spectra in the early stage of the plasma formation are very effective to prevent self-absorption to improve the LIBS analytical performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.27.002509 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!