We present a Mach-Zehnder-like interferometer capable of simultaneous super-octave (950 - 2100 nm) destructive interference with an intensity extinction of 4 × 10. Achromatic nulling is achieved by unbalancing the number of Fresnel reflections off optically denser media in the two interferometer arms. With a methane gas sample in one interferometer arm, we isolate the coherent molecular vibrational emission from the broadband, impulsive excitation and quantitatively examine the potential improvement in detectable concentration, compared to direct transmission geometry. The novel concept will benefit sensing applications requiring high detection sensitivity and dynamic range, including time-domain and frequency-domain spectroscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.002432DOI Listing

Publication Analysis

Top Keywords

broadband interferometric
4
interferometric subtraction
4
subtraction optical
4
optical fields
4
fields mach-zehnder-like
4
mach-zehnder-like interferometer
4
interferometer capable
4
capable simultaneous
4
simultaneous super-octave
4
super-octave 950
4

Similar Publications

Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories.

Rev Sci Instrum

January 2025

OzGrav-ANU, ARC Centre for Gravitational Astrophysics, College of Science, The Australian National University, Canberra ACT2601, Australia.

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10-16m/Hz at 1 kHz. This sensitivity is necessary for future tests of thermal noise models on cross sections of silicon suspension samples proposed for future gravitational-wave detectors. A volume of ∼36 l is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise.

View Article and Find Full Text PDF

Hanbury-Brown and Twiss (HBT) effect is the foundation for stellar intensity interferometry. However, it is a phase insensitive two-photon interference effect. Here we extend the HBT interferometer by mixing intensity-matched reference fields with the input fields before intensity correlation measurement.

View Article and Find Full Text PDF

Extreme ultraviolet pulses as generated by high harmonic generation (HHG) are a powerful tool for both time-resolved spectroscopy and coherent diffractive imaging. However, the integration of spectroscopy and microscopy to harness the unique broadband spectra provided by HHG is hardly explored due to the challenge to decouple spectroscopic and microscopic information. Here, we present an interferometric approach to this problem that combines Fourier transform spectroscopy (FTS) with Fourier transform holography (FTH).

View Article and Find Full Text PDF

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal.

View Article and Find Full Text PDF

A coherent perfect absorber exploits the interferometric nature of light to deposit all of a light field's incident energy into an otherwise weakly absorbing sample. The downside of this concept is that the necessary destructive interference in coherent perfect absorbers gets easily destroyed both by spectrally or spatially detuning the incoming light field. Each of these two limitations has recently been overcome by insights from exceptional-point physics and by using a degenerate cavity, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!