A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Standardization of relative centrifugal forces in studies related to platelet-rich fibrin. | LitMetric

Standardization of relative centrifugal forces in studies related to platelet-rich fibrin.

J Periodontol

FORM, Frankfurt Oral Regenerative Medicine, Clinic for Maxillofacial and Plastic Surgery, Johann Wolfgang Goethe University, Frankfurt Am Main, Germany.

Published: August 2019

Platelet-rich fibrin (PRF), a second-generation platelet concentrate, has been the focus of intensive research endeavors over the past 2 decades. Over the years, however, numerous reports have inaccurately reported relative centrifugal force (RCF) values, which has caused considerable confusion in the field. Furthermore, the use of trade names such as leukocyte and platelet-rich fibrin (L-PRF) and advanced platelet-rich fibrin (A-PRF) has further confused many readers, since studies have not always used centrifugation parameters with equal rotor sizes, angulation of tubes, and/or tube design. This has led to considerable misperception in the report of relative centrifugal force. Herein is described necessary parameters pivotal for the future report of RCF in studies related to PRF, which include: 1) dimensions of the rotor (radius at the clot and end of the tube); 2) rotor angulation for the tube holder; 3) revolutions per minute (RPM) and time; 4) RCF value calculated at either the RCF-minimum, RCF-clot, or RCF-maximum; 5) composition and size of tubes used to produce PRF; and 6) centrifugation model used. This editorial aims to minimize confusion in the field and create more transparent research reporting RCF values in future studies.

Download full-text PDF

Source
http://dx.doi.org/10.1002/JPER.18-0553DOI Listing

Publication Analysis

Top Keywords

platelet-rich fibrin
16
relative centrifugal
12
centrifugal force
8
rcf values
8
confusion field
8
standardization relative
4
centrifugal forces
4
studies
4
forces studies
4
platelet-rich
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!