A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

EP15A3 Based Precision and Trueness Verification of VITROS HbA1C Immunoassay. | LitMetric

EP15A3 Based Precision and Trueness Verification of VITROS HbA1C Immunoassay.

Indian J Clin Biochem

2Department of Clinical Biochemistry, MIOT Hospitals, No. 4/112, Mount Poonamallee Road, 4th Cross St, Sathya Nagar, Manapakkam, Chennai, Tamil Nadu 600089 India.

Published: January 2019

Verification of analytical performance of measurands becomes an essential requirement for the laboratories before proceeding to patients' samples testing. In our study we have verified the performance of HbA1C Immunoturbidimetric assay (VITROS 5600) against manufacturers' claims using CLSI EP15A3 Guidelines. We performed our study using two concentrations of Quality Control from Bio-Rad (Level 1 and Level 2). A precision verification study was carried out using five replicates of QC per day for five days following which imprecision estimates in form of Within Run (Repeatability) %CV and Within Lab %CV were calculated and compared against manufacturer's claims. Second part of our study included derivation of grand mean from the results of 25 replicates of QC used for precision verification. This was compared against the Target Value of the assigned QC obtained from the peer group mean of laboratories participating in interlaboratory QC program (unityTM Interlab-Bio-Rad) for %bias estimation. The findings of our precision study showed an acceptable Within Lab imprecision (%CV-0.6%), while the %CV -repeatability (%CV-0.54%) was greater than the manufacturer's claim (σR-0.5%). Hence upper verification limit for the manufacturer's claim (0.65%) was calculated against which the %CV Repeatability was compared and was found to be acceptable. The trueness verification showed that our grand mean (5.488%) was within the verification interval of the target value (5.462-5.497%) and hence the actual %bias was not statistically significant. Our study demonstrates that HbA1C immunoassay shows an acceptable performance consistent with the manufacturer's claims.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6346623PMC
http://dx.doi.org/10.1007/s12291-017-0712-zDOI Listing

Publication Analysis

Top Keywords

trueness verification
8
hba1c immunoassay
8
precision verification
8
manufacturer's claims
8
manufacturer's claim
8
verification
7
study
6
ep15a3 based
4
precision
4
based precision
4