Diagnostic assays for molecular alterations highly correlated with prognosis, predictive efficacy or safety of therapeutics are valuable clinical tools and in some cases approved as companion diagnostics (CDx) by the Federal Food and Drug Administration. For example, assays that determine echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) translocation status have been approved as CDx assay for therapies that target this molecular alteration. Characterizing the parameters that may compromise diagnostic accuracy for molecular biomarkers is critical for optimal patient care. To investigate the impact of pre-analytical handling and processing of tumor tissue on commonly used diagnostic immunohistochemistry-based assays for ALK and mesenchymal epithelial transition protein [c-mesenchymal epithelial transition (c-MET)], we investigated the effects of cold ischemia, fixative type, fixation time, and cut-slide age on staining consistency and intensity using human lung xenograft tumor tissue. Cold ischemia times for up to 5 to 6 hours for c-MET or ALK, respectively had minimal impact on staining. The optimal fixation conditions for both assays were found to be at least 6 hours and up to 48 hours for c-MET or 72 hours for ALK, in 10% neutral buffered formalin and Zinc formalin. The ALK antigen demonstrated marked staining intensity differences across non-neutral buffered formalin fixative types and times. Finally, cut-slide age influenced assay performance for both ALK and c-MET, with maximum stability observed when cut slides were stored at ambient temperatures (30°C) for no longer than 3, and 5 months, respectively. This study highlights the potential for pre-analytical factors to confound diagnostic test result interpretation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7253184 | PMC |
http://dx.doi.org/10.1097/PAI.0000000000000730 | DOI Listing |
Clin Chem Lab Med
January 2025
Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada.
Objectives: Careful consideration of the pre-analytical process for urine examination is essential to avoid errors and support accurate results and decision-making. Our objective was to assess the impact of various pre-analytical factors on urine test strip and quantitative chemistry results, including stability, tube type, fill volume, and centrifugation.
Methods: Residual random urine specimens were identified.
Pathologica
October 2024
Division of Experimental Oncology, Istituto Europeo di Oncologia, IRCCS, Milano.
Objective: Prostate cancer (PCa) is the most common cause of cancer-related deaths in men worldwide. BRCA1/2 genes are reported altered in approximately 1% and 8% of PCa cases, respectively. To date, formalin-fixed paraffin-embedded (FFPE) tissues have a consolidate use in the clinical practice, but with a significant drawback related to DNA/RNA degradation during the pre-analytical process.
View Article and Find Full Text PDFAnn Clin Biochem
January 2025
Department of Clinical Chemistry, University Hospitals Sussex NHS Trust, Chichester, UK.
Background: Grossly lipaemic samples are a significant cause of analytical errors, potentially impacting patient care. The causes of lipaemia are varied and often unavoidable, while methods to reduce lipaemia through gold-standard ultracentrifugation are limited by availability, transportation and cost. Benchtop centrifugation has been proposed as an alternative method to reduce lipaemia.
View Article and Find Full Text PDFAdv Lab Med
December 2024
Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy.
Objectives: Urinalysis is widely used and is also frequently requested in emergency situations for screening hypovolemia, urinary tract infections, diabetes, ketoacidosis and hematuria. Our aim was to evaluate the impact of reporting urinary sediment in emergency department specimens with the Sysmex UN system.
Methods: We evaluated urinalyses requested by the emergency department over a three-month period and examined red blood cell count interference, compared leukocyte esterase dipsticks to cytofluorimetric leukocyte count and nitrites to cytofluorimetric bacterial count.
Anticancer Res
December 2024
Department of Surgery, Yokohama City University, Yokohama, Japan.