A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carbonic Acid Eluent Ion Chromatography. | LitMetric

Carbonic Acid Eluent Ion Chromatography.

Anal Chem

Department of Chemistry and Biochemistry , University of Texas at Arlington, Arlington , Texas 76019-0065 , United States.

Published: March 2019

Alkali metals, amines and alkanolamines are separated on a poly(butadiene)-maleic acid on silica stationary phase using a carbonic acid (HCO*) eluent with and without a mineral acid. The HCO* eluent is prepared in situ by high pressure permeative introduction of gaseous CO through thin membranes supported upon a porous steel disk. The permeation flux and thus the eluent concentration is controlled by varying the applied CO pressure. This novel frit-supported membrane device tolerates much higher liquid and gas pressures than Teflon AF capillaries, permitting [HCO*] exceeding 0.53 M and attaining a pH of 3.3. Silicone was presently preferred over Teflon AF, both as planar membranes, as mechanical properties of the latter change as large amounts of CO dissolve in it. After separation, the CO can be efficiently removed via another gas permeable membrane device permitting detection of the eluting bicarbonate salt conductometrically in a background of nearly pure water. Most analytes are more sensitively detected after anion conversion to hydroxide using a standard suppressor, permitting 3-17 pmol LODs on 2 mm bore columns. The data, particularly comparisons with an HNO eluent, with or without HCO*, indicate that proton exchange alone does not account for the retention behavior; some reactive addition of HCO is involved.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b05627DOI Listing

Publication Analysis

Top Keywords

carbonic acid
8
acid hco*
8
hco* eluent
8
membrane device
8
eluent
5
acid eluent
4
eluent ion
4
ion chromatography
4
chromatography alkali
4
alkali metals
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!