A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enhanced tetracycline removal by in-situ NiFe nanoparticles coated sand in column reactor. | LitMetric

The occurrence of various antibiotics in natural waters poses an emerging environmental concern. Tetracycline (TC) is a frequently used antibiotic in human therapy, veterinary industry, and agricultural sectors. In the current study, TC removal from aqueous solutions was studied using binary Nickel/nano zero valent iron particles (NiFe nano particles) and in-situ NiFe nanoparticles coated sand (IS-NiFe). Removal of TC using bimetallic NiFe particles was optimized with help of response surface methodology (RSM). Using the optimized parameters (concentration of TC: 20 mg/L; NiFe dose: 120 mg/L; time of interaction: 90 min), 99.43 ± 0.98% removal of TC was noted. Further, IS-NiFe was packed in the column reactors and effects of different parameters like flow rate (1-3 mL/min), bed height (3-10 cm) and inlet TC concentration (20-60 mg/L) on breakthrough characteristics were examined. Under the optimized conditions the removal capacity in the column reactor was 1198 ± 40.2 mg/g using IS-NiFe. The column kinetic data were successfully fitted with Adams- Bohart and Thomas models. TC removal efficiency of IS-NiFe in column reactors was tested with TC (20 mg/L) spiked lake water, ground water, and tap water and the removal capacity was noted to be 698.55 ± 11.21, 764.17 ± 6.78, and 801.7 ± 13.26 mg/g respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvman.2019.01.109DOI Listing

Publication Analysis

Top Keywords

in-situ nife
8
nife nanoparticles
8
nanoparticles coated
8
coated sand
8
column reactor
8
column reactors
8
removal capacity
8
is-nife column
8
removal
7
nife
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!