Frequency of anesthetic overdose with mean alveolar concentration-guided anesthesia at high altitude.

Med Gas Res

Vascular Function Research Laboratory, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.

Published: January 2019

This study reported the frequency of anesthetic overdose measured with the bispectral index in a high altitude city (Bogotá-Colombia, 2600 meters above sea level). We assembled a prospective cohort of patients. Preoperative variables were described, and 10 minutes after the surgical incision, bispectral index, mean alveolar concentration, mean arterial pressure, and oxygen saturation were recorded. Bispectral index was classified as superficial (60), adequate (40-60), and deep (> 40). Mean alveolar concentration was classified as low (< 0.8), normal (0.8-1.2), and high (> 1.2). We included 50 patients. The mean age of the patients was 36.3 ± 13.5 years; 48% were male and 78% were categorized as ASA I. Mean values of mean alveolar concentration and bispectral index were 1.14 ± 0.18 and 38.66 ± 6.9, respectively. Frequency of anesthetic overdose measured with bispectral index was 54% and only 20% with mean alveolar concentration. In total, 78% of patients received normal mean alveolar concentration values, and among these patients, 49% had deep bispectral index levels and 51% were adequate. There was no correlation between mean alveolar concentration and bispectral index (Pearson = 0.161, = 0.246) or between bispectral index and mean arterial pressure (Pearson = 0.367, = 0.08). All patients older than 60 years exhibited deep bispectral index levels, and although we did not identify a correlation between age and bispectral index, a tendency was observed (Pearson = -0.087, = 0.538). Safe and effective anesthesia overdose could be a common phenomenon. Bispectral index-guided anesthesia could be a helpful and reliable tool in the assessment and prevention of anesthesia overdose at high altitude. The study was approved by the ethics committee of the Fundación Cardioinfantil-Instituto de cardiología, Bogota, Colombia (approved number: 312017).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352576PMC
http://dx.doi.org/10.4103/2045-9912.248265DOI Listing

Publication Analysis

Top Keywords

alveolar concentration
24
frequency anesthetic
12
anesthetic overdose
12
high altitude
12
bispectral
11
altitude study
8
overdose measured
8
measured bispectral
8
arterial pressure
8
concentration bispectral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!