Introduction: In iodine-131 (I-131) imaging, the image quality is degraded by scatter and penetration in a collimator. In this work, we assessed the penetrated and the scattered photon fractions in the photopeak energy window using Monte Carlo Simulation code.
Materials And Methods: The Siemens Medical System equipped with high-energy collimator was simulated. We evaluated the acceptance angle values on geometric, penetration, and scatter components in a separate file. Binary images in a data file are obtained and each one of them was imported in software ImageJ. Full-width at half-maximum (FWHM) and sensitivity were calculated and compared.
Results: The simulation data show that for the acceptance angle value equal to 4.845°, the geometric, scatter, and penetration components were 93.20%, 4.13%, and 2.67%, respectively. Moreover, the resolution is improved (FWHM = 7.21 mm, full width at tenth maximum = 12.36 mm) for a point source at 12 cm from the detector.
Conclusion: The small acceptance angle has a major impact on the image quality in I-131 single photon emission computed tomography.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352644 | PMC |
http://dx.doi.org/10.4103/ijnm.IJNM_109_18 | DOI Listing |
J Food Sci Technol
February 2025
Program of Medical Technology, Faculty of Allied Health Sciences, Chonburi, 20130 Thailand.
Unlabelled: The aim of this study was to utilize four rice pasta by-products (RPB), including white rice pasta, black jasmine rice pasta, red jasmine rice pasta and brown rice pasta, to ferment into four vinegars. The dynamic variations during fermentation and their quality were evaluated. During alcoholic fermentation, the saccharified substrates were fermented with for 12 days, resulting in an alcohol yield of approximately 10% (v/v) after 4 days of fermentation.
View Article and Find Full Text PDFProc Inst Mech Eng H
January 2025
Department of Biomedical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India.
Assessing the kinematics of the upper limbs is crucial for rehabilitation treatment, especially for stroke survivors. Nowadays, researchers use computer vision-based algorithms for Human motion analysis. However, specific challenges include less accuracy, increased computational complexity and a limited number of anatomical key points.
View Article and Find Full Text PDFJ Biomech
January 2025
Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University Chengdu Sichuan Province China. Electronic address:
OpenCap, a smartphone-based markerless system, offers a cost-effective alternative to traditional marker-based systems for gait analysis. However, its kinematic measurement accuracy must be evaluated before widespread use in clinical practice. This study aimed to evaluate OpenCap for lower-limb joint angle measurements during walking in patients with knee osteoarthritis (OA) and to compare error metrics between patients and healthy controls.
View Article and Find Full Text PDFKnee Surg Relat Res
January 2025
Department of Orthopedic Surgery, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yeongeon-Dong, Jongno-Gu, Seoul, 03080, Korea.
Background: Patellofemoral pain syndrome (PFPS) is one of the most common conditions affecting the knee joint, yet its pathomechanics remain unclear. The aim of this study was to investigate changes in muscle activation and gait patterns and to analyze the relationship between muscle activation and kinetic gait patterns in patients with PFPS.
Methods: This study included 31 patients with PFPS and 28 healthy volunteers without any symptoms.
Eur J Trauma Emerg Surg
January 2025
3D-Lab, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.
Purpose: Currently, no gold standard exists for 3D analysis of virtually planned surgery accuracy postoperatively. The aim of this study was to present a new, validated and standardised methodology for 3D postoperative assessment of surgical accuracy in patients undergoing 3D virtually planned and guided corrective osteotomies.
Methods: All patients who underwent 3D planned corrective osteotomy in 2021-2022 at our center with a postoperative CT were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!