Severity: Warning
Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aminopeptidase N, also known as CD13, is a transmembrance protease with many functions. CD13 is involved in inflammatory diseases and cancers. A convenient and reliable laboratory test method for detecting the suppressing effects of enzyme activity would be useful for study of CD13 inhibitors. Porcine CD13 (pCD13) was traditionally considered an enzyme source but has significant practical disadvantages. pCD13 is not a human source, and the accuracy and reliability of experimental results are greatly reduced. In this study, a modified detection method with K562-CD13 monoclonal cells, a human-derived cell line, was established to detect the suppressing effects of enzyme activity by the CD13 inhibitor. In this method, K562-CD13 monoclonal cells were used as enzyme source and L-leucine p-nitroaniline hydrochloride as substrate. Using CD13 enzyme activity analyses, we found that the ability of the catalytic substrate was weaker in K562 cells than in the other cell lines, and K562-CD13 cells expressed significantly higher levels of CD13 enzyme activity than parental K562 cells. The enzyme activity of CD13 was detected with the new method after ubenimex treatment. The enzyme activity was significantly inhibited by ubenimex in a dose-dependent manner. In summary, this study proposes a sensitive, stable, and objective laboratory method for detecting the inhibitory effect of the CD13 inhibitor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1248/cpb.c18-00667 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!