A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectrophotometric flow injection determination of dissolved titanium in seawater exploiting in-line nitrilotriacetic acid resin preconcentration and a long path length liquid waveguide capillary cell. | LitMetric

A sensitive spectrophotometric method for the determination of dissolved titanium (Ti) in seawater is developed. It involves in-line preconcentration and a long path length liquid waveguide capillary cell (LWCC). Nitrilotriacetic acid (NTA) resin is used to preconcentrate Ti from ∼25 mL seawater sample at pH 1.7, and elution is accomplished with 0.8 mol L hydrochloride acid. The eluted Ti solution is buffered to pH 6.0 with 1.0 mol L ammonium acetate and mixed with 1.5 mmol L Tiron solution. The mixture is then injected into LWCC and measured by spectrophotometry at 420 nm. Before the preconcentration step, the sample is treated with 7 mmol L ascorbic acid to reduce Fe(III) to Fe(II), in order to eliminate the Fe interference. The method is not interfered by Fe(III) and Cu(II) present in seawater samples at concentrations 50-fold higher in relation to Ti, and by Cd(II), Pb(II), Cr(VI), Mn(II), Al(III), Zn(II), and Ni(II) at concentrations 100-fold higher in relation to Ti. It is time efficient (7.5 minutes per sample), sensitive (0.10 nmol L detection limit), precise (1.40% measurement RSD at 1.00 nmol L Ti) and is characterized by a linear range of 0.50-5.00 nmol L Ti. The method was applied to analysis of natural water samples collected from the Jiulongjiang Estuary, Fujian, China.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2018.11.034DOI Listing

Publication Analysis

Top Keywords

determination dissolved
8
dissolved titanium
8
titanium seawater
8
nitrilotriacetic acid
8
preconcentration long
8
long path
8
path length
8
length liquid
8
liquid waveguide
8
waveguide capillary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!