A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

How Well Do Results From Randomized Clinical Trials and/or Recommendations for Implantable Cardioverter-Defibrillator Programming Diffuse Into Clinical Practice?. | LitMetric

AI Article Synopsis

  • Inappropriate programming of implantable cardioverter-defibrillators (ICDs) can cause harm, and there has been little research on how guidelines affect actual practice.
  • The study analyzed data from 232,982 ICD recipients from 2008 to 2017 to see the impact of two key publications (MADIT-RIT trial and Consensus Statement) on programming practices.
  • Initial adoption of recommended programming settings increased significantly after the MADIT-RIT publication, but overall implementation remained low and the effect of subsequent recommendations was minimal, highlighting significant variability in practices across different hospitals and regions.

Article Abstract

Background Inappropriate implantable cardioverter-defibrillator programming can be detrimental. Whether trials/recommendations informing best implantable cardioverter-defibrillator programming (high-rate cutoff and/or extended duration of detection) influence practice is unknown. Methods and Results We measured reaction to publication of MADIT-RIT (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy; 2012) and the Consensus Statement (2015) providing generic programming parameters, in a national cohort of implantable cardioverter-defibrillator recipients, using the ALTITUDE database (Boston Scientific). Yearly changes in programmed parameters to either trial-specified or class 1 recommended parameters (≥185 beats per minute or delay ≥6 seconds) were assessed in parallel. From 2008 to 2017, 232 982 patients (aged 67±13 years; 28% women) were analyzed. Prevalence of MADIT- RIT -specific settings before publication was <1%, increasing to 13.6% in the year following. Thereafter, this increased by <6% over 5 years. Among preexisting implants (91 171), most patients (58 739 [64.4%]) underwent at least 1 in-person device reprogramming after trial publication, but <2% were reprogrammed to MADIT - RIT settings. Notably, prevalence of programming to ≥185 beats per minute or delay ≥6 seconds was increased by MADIT - RIT (57.4% in 2013 versus 40.2% at baseline), but the following publication of recommendations had minor incremental effect (73.2% in 2016 versus 70.8% in 2015). High-rate cutoff programming was favored almost 2-fold compared with extended duration throughout the test period. Practice changes demonstrated large interhospital and interstate variations. Conclusions Trial publication had an immediate effect during 1 year postpublication, but absolute penetration was low, and amplified little with time. Consensus recommendations had a negligible effect. However, generic programming was exercised more widely, and increased after trial publication, but not following recommendations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6405582PMC
http://dx.doi.org/10.1161/JAHA.117.007392DOI Listing

Publication Analysis

Top Keywords

implantable cardioverter-defibrillator
16
cardioverter-defibrillator programming
12
well randomized
4
randomized clinical
4
clinical trials
4
trials and/or
4
and/or recommendations
4
implantable
4
recommendations implantable
4
cardioverter-defibrillator
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!