  • Robotic C-arm CBCT systems are crucial for interventional cardiac procedures and precision radiotherapy but face challenges like heart motion causing image blurring.
  • Conventional cardiac imaging methods often use retrospective gating, leading to image artefacts and increased radiation exposure.
  • The new ACROBEAT protocol improves image quality and efficiency by using real-time ECG signals to optimize imaging, resulting in significant enhancements in contrast-to-noise ratio and a reduction in scan time and projections needed.

Article Abstract

Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi-sweep retrospective ECG gated acquisition.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab03f4DOI Listing

Publication Analysis

Top Keywords

cone beam
12
beam computed
12
computed tomography
12
patient connected
8
connected imaging
8
adaptive cardiac
8
cardiac cone
8
conventional multi-sweep
8
multi-sweep retrospective
8
retrospective ecg
8

Similar Publications

Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.

Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.

View Article and Find Full Text PDF

Evaluation of sticky bone in guided bone regeneration in the aesthetic area of the anterior teeth: a retrospective study.

Int J Oral Maxillofac Surg

January 2025

Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:

The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.

View Article and Find Full Text PDF

Finite model analysis of different anchorage sites for bone-supported facemask application in unilateral cleft lip and palate.

Am J Orthod Dentofacial Orthop

January 2025

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:

Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.

Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.

View Article and Find Full Text PDF

Introduction: This study aimed to assess the root resorption and alveolar bone changes of maxillary incisors volumetrically and 3-dimensionally in patients with Class II Division 1 malocclusion who underwent treatments involving the extraction of 4 first premolars with conventional fixed appliances (FAs) vs clear aligners (CAs).

Methods: A total of 320 maxillary incisors from 80 patients were assessed and divided into 2 groups (FAs and CAs), each possessing similar baseline characteristics. Pretreatment and posttreatment cone-beam computed tomography scans were used to analyze linear and volumetric orthodontically induced inflammatory root resorption, alveolar bone thickness (ABT), alveolar bone height (ABH), as well as anteroposterior and vertical movements of maxillary incisors.

View Article and Find Full Text PDF

: Sinus lifting, a procedure to augment bone in the maxilla, may cause complications such as sinusitis due to impaired drainage. This study aimed to assess how sinus lifting impacts airflow in the sinus cavity, which is essential for patients undergoing dental implants. Using computational fluid dynamics (CFD), this research analyzed airflow changes after sinus floor elevation, offering insights into the aerodynamic consequences of the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!