A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multifunctional N,S co-doped carbon dots for sensitive probing of temperature, ferric ion, and methotrexate. | LitMetric

In this paper, we have presented a facile method to fabricate nitrogen and sulfur co-doped carbon dots (N,S-CDs) for blood methotrexate (MTX) sensing applications. The N,S-CDs with quantum yield up to 75% were obtained by one-step hydrothermal carbonization, using reduced glutathione and citric acid as the precursors. With this approach, the formation and the surface passivation of N,S-CDs were carried out simultaneously, resulting in intrinsic fluorescence emission. Owing to their pronounced temperature dependence of the fluorescence emission spectra, resultant N,S-CDs can work as versatile nanothermometry devices by taking advantage of the temperature sensitivity of their emission intensity. In addition, the obtained N,S-CDs facilitated high selectivity detection of Fe ions with a detection limit as low as 0.31 μM and a wide linear range from 3.33 to 99.90 μM. More importantly, the added MTX selectively led to the fluorescence quenching of the N,S-CDs. Such fluorescence responses were used for well quantifying MTX in the range of 2.93 to 117.40 μM, and the detection limit was down to 0.95 μM. Due to "inert" surface, the N,S-CDs well resisted the interferences from various biomolecules and exhibited excellent selectivity. The proposed sensing system was successfully used for the assay of MTX in human plasma. Due to simplicity, sensitivity, selectivity, and low cost, it exhibits great promise as a practical platform for MTX sensing in biological samples. Graphical Abstract.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-019-01617-4DOI Listing

Publication Analysis

Top Keywords

co-doped carbon
8
carbon dots
8
mtx sensing
8
fluorescence emission
8
detection limit
8
ns-cds
7
mtx
5
multifunctional co-doped
4
dots sensitive
4
sensitive probing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!