This paper compares two types of microfluidic sensors that are designed for operation in ISM (Industrial, Scientific, Medical) bands at microwave frequencies of 2.45 GHz and 5.8 GHz. In the case of the first sensor, the principle of operation is based on the resonance phenomenon in a microwave circuit filled with a test sample. The second sensor is based on the interferometric principle and makes use of the superposition of two coherent microwave signals, where only one goes through a test sample. Both sensors are monolithic structures fabricated using low temperature co-fired ceramics (LTCCs). The LTCC-based microwave-microfluidic sensor properties are examined and compared by measuring their responses for various concentrations of two types of test fluids: one is a mixture of water/ethanol, and the other is dopamine dissolved in a buffer solution. The experiments show a linear response for the LTCC-based microwave-microfluidic sensors as a function of the concentration of the components in both test fluids.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6386962PMC
http://dx.doi.org/10.3390/s19030577DOI Listing

Publication Analysis

Top Keywords

microwave-microfluidic sensors
8
low temperature
8
temperature co-fired
8
test sample
8
ltcc-based microwave-microfluidic
8
test fluids
8
monolithic microwave-microfluidic
4
sensors
4
sensors low
4
co-fired ceramic
4

Similar Publications

Background: This research is focused on the design of highly sensitive microfluidic sensors for the applications in liquid dielectric characterizations including biomedical samples.

Methods: Considering the narrow-band operation of microfluidic sensors based on microwave resonators, in this study, microfluidic sensors based on the variation of transmission phase in microwave transmission lines (TLs) are proposed. It is shown that among different microwave TLs, slot-lines are an appropriate type of TL for sensing applications because a major portion of the electromagnetic (EM) field passes above the line, where a microfluidic channel can be easily devised.

View Article and Find Full Text PDF

A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer (MIP) is presented. The sensing device is based on a stub resonator to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the selectivity of the sensor and hence the sensitivity compared to the uncoated or to the coated with non-imprinted polymer (NIP) sensor.

View Article and Find Full Text PDF

This paper presents a microwave microfluidic biosensor for monitoring blood glucose levels. The glucose sensor is a triple ring microstrip patch antenna integrated with a biomimetic microfluidic device capable of measuring a fixed volume of glucose solution. The sensor was utilized to detect 50-500 mg/dL glucose solutions.

View Article and Find Full Text PDF

The global COVID-19 pandemic caused by SARS-CoV-2 has resulted in an unprecedented economic and societal impact. Developing simple and accurate testing methods for point-of-care (POC) diagnosis is crucial not only for the control of COVID-19, but also for better response to similar outbreaks in the future. In this work, we present a novel proof-of-concept of a microfluidic microwave sensing method for POC diagnosis of the SARS-CoV-2 virus.

View Article and Find Full Text PDF

This paper presents a Peano fractal geometry complementary split ring resonator (PFCSRR) loaded microstrip transmission line with a microfluidic channel for equol (EQ) sensing in a high and wide range of concentrations in aqueous solution. The proposed sensor was designed based on a CSRR loaded microstrip line with a Peano fractal in the center of a CSRR and validated through simulation and experiment. The microfluidic channel was fabricated using polydimethylsiloxane (PDMS) and installed to cover the sensing area.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!