Current study focusses on the concomitant production of fatty acid methyl ester (FAME, biodiesel) and exopolysaccharides (EPS) from Scenedesmus abundans cell factory in flat panel photobioreactor using cost effective harvesting strategy. Parallel mini and medium scale flat panel photobioreactors (PBRs) with special gas sparging system enabling high gas to liquid mass transfer and efficient mixing were designed. Biomass titer of 6.9 g/l with overall biomass productivity of 1.2 g/l/day was achieved with constant high light intensity of 2162 µE/m/s in growth phase (134 h) using optimum nutrient concentration. FAME concentration of 1.53 g/l was achieved after 15 days of nitrogen deprivation condition with productivity of 67 mg/l/day. The EPS production of 236 mg/l with a yield of 37 mg/g biomass was achieved. The strain proved its capability to produce multiproducts simultaneously in a single stage PBR by natural autoflocculation harvesting technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biortech.2019.01.091 | DOI Listing |
Nanomaterials (Basel)
December 2024
Division of Physics, Engineering, Mathematics and Computer Sciences and Optical Science Center for Applied Research, Delaware State University, Dover, DE 19901, USA.
This study offers a comprehensive summary of the current states as well as potential future directions of transparent conducting oxides (TCOs), particularly tin-doped indium oxide (ITO), the most readily accessible TCO on the market. Solar cells, flat panel displays (FPDs), liquid crystal displays (LCDs), antireflection (AR) coatings for airbus windows, photovoltaic and optoelectronic devices, transparent p-n junction diodes, etc. are a few of the best uses for this material.
View Article and Find Full Text PDFInjury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFEur J Radiol
December 2024
The Health Information and Quality Authority (HIQA), Unit 1301, City Gate, Mahon, Cork, T12 Y2xt Cork, Ireland. Electronic address:
Purpose: The purpose of this work was to establish national Irish diagnostic reference levels (DRLs) for a clinically representative and comprehensive list of clinical indications, anatomical regions, and common procedures for fluoroscopy and fluoroscopically guided interventions and compare these, where possible, to other DRLs established at a national level.
Method: A list of clinical indications, anatomical regions and common procedures was established. A national database of service providers was used to identify all medical radiological facilities providing fluoroscopy and fluoroscopically guided intervention services.
Eur Urol Open Sci
January 2025
Department of Urology, Amsterdam UMC, Amsterdam, The Netherlands.
Background And Objective: Urothelial bladder cancer (UCB) care requires frequent follow-up cystoscopy and surgery. Confocal laser endomicroscopy (CLE), a probe-based optical technique for real-time microscopic evaluation, has shown promising accuracy for grading of UCB. We investigated the diagnostic accuracy of CLE-based assessment of the surgical radicality of the bladder resection bed (RB).
View Article and Find Full Text PDFOnt Health Technol Assess Ser
December 2024
Background: In medicine, x-rays are used to generate images of tissues and structures inside the body. X-rays are emitted by a source device and, after passing through the body, strike a detector, which forms an image of the tissues and structures the x-rays passed through. Dual-energy subtraction (DES) x-ray systems use radiation of different energy spectra (energy levels) and the principle of differential absorption characteristics of bone and soft tissue to produce separate bone and soft tissue x-ray images, in addition to a conventional x-ray image.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!