Purpose: This study uses intentionally tilted implants with a moderate insertion torque to retain an immediately loaded fixed full-arch implant-retained prosthesis using four implants. The aims of this study were to determine the likelihood that this type of implant-retained prosthesis can be predictably provided on the day of implant placement, the survival rate when providing immediate load, and the importance of insertion torque on the survival of the implants.
Materials And Methods: All implants that were placed after August 1, 2015 and before December 31, 2016 at the ClearChoice Dental Implant Center of Minneapolis were recorded. The performance of these implants was followed to determine the success rate in the category of "intention to treat" where the treatment is provided on the same day as implant placement. Insertion torque was recorded for all implants. Implants were followed to determine survival of the implants and complications observed.
Results: Between August 1, 2015 and December 31, 2016, a total of 1,903 implants were placed. These implants were utilized to support 441 prostheses, with 440 actually being restored with a provisional prosthesis on the day of implant placement. Mean follow-up time was 484 days with a maximum of 972 days and a median of 474 days. A total of 36 implants failed to achieve osseointegration, resulting in an overall survival rate of 98.1% with a confidence interval (CI) of 98.7% to 97.5%. Survival was 97.6% in the maxilla and 98.9% in the mandible. Insertion torque of less than 15 Ncm (n = 80, 77 survival), between 15 and 34 Ncm (n = 122, 120 survival), and greater than 35 Ncm (n = 1,701, 1,670 survival) demonstrated no difference in implant survival.
Conclusion: Based on this study of 1,903 implants placed between August 1, 2015 and December 31, 2016, the following observations were made: (1) this surgical/prosthetic treatment approach succeeded in the "intention to treat" category with 440/441 (99.8%) prostheses inserted on the day of implant surgery; (2) overall implant survival was 98.1%; (3) insertion torque appeared to have no effect on implant survival.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.7193 | DOI Listing |
J Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
Front Bioeng Biotechnol
December 2024
Department of Spine Surgery, The Affiliated Hospital of Qingdao University, Qindao, China.
Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.
View Article and Find Full Text PDFEur J Orthod
December 2024
Department of Dentistry, All India Institute of Medical Sciences, Basni Industrial Area Phase-2, Jodhpur- 342005, Rajasthan, India.
Background: The infrazygomatic miniscrew implants (IZC-MSI) serve as innovative temporary anchorage devices placed parallel to the roots of molars in the infrazygomatic crest region, leveraging their extra-radicular location to support the en masse distalization and intrusion of the maxillary dentition. The efficacy and stability of these screws are crucial for their application in contemporary orthodontic practices.
Objectives: This systematic review aimed to estimate the success rate and factors affecting the stability of IZC-MSI.
Adv Sci (Weinh)
December 2024
School of Electronic Science and Engineering, Nanjing University, Nanjing, 210023, China.
The prevailing research emphasis has been on reducing the critical switching current density (J) by enhancing the damping-like efficiency (β). However, recent studies have shown that the field-like efficiency (β) can also play a major role in reducing J. In this study, the central inversion asymmetry of Pt-Co is significantly enhanced through interface engineering at the sub-atomic layer of Ta, thereby inducing substantial alterations in the β associated with the interface.
View Article and Find Full Text PDFClin Implant Dent Relat Res
December 2024
Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
Introduction: Short implants are today a reliable, minimally invasive option for the rehabilitation of the posterior maxilla. However, maintaining marginal bone stability remains a crucial factor for long-term success, particularly in the case of short implants. The present multicenter prospective case-control study aimed to compare the clinical outcomes of bone-level and tissue-level short implants in the posterior maxilla, focusing on implant survival and peri-implant marginal bone stability over 1 year of function.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!